Two rows on every air-cooled sheet
Each air-cooled spec sheet measures at 23 ft (7 m) from the front, once at normal load and once in Quiet-Test low-speed exercise. The first row reads "Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load", and the second "Sound output in dB(A) at 23 ft (7 m) with generator in Quiet-Test™ low-speed exercise mode".
One footnote covers both: "Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters."
These are A-weighted sound pressure levels taken 7 meters out. The normal-load row is what you hear while the power is out. The exercise row is the short weekly or fortnightly self-test that keeps the engine ready, and because it runs whether or not the power ever fails, it is the Generac noise the street hears most often.
The two rows never meet in a ranking here, and the gap between them is wide. On the 7257, 49 dB(A) in exercise and 61 at normal load sit 12 dB(A) apart. Since 10 dB is roughly what the ear hears as twice as loud, its outage running is more than twice as loud as its weekly test. Put Generac's numbers on a decibel chart of everyday sounds by all means, but keep the two rows apart.
How loud is a Generac generator during its weekly exercise?
Between 49 and 58 dB(A) in Quiet-Test low-speed exercise for the air-cooled models. Two lines are sold side by side, newer models with the Power Zone 200 controller and the Guardian series with the Evolution controller, and each also comes bundled with a transfer switch; the bundles share the generator's figures.
| Exercise, 23 ft (7 m), front | Models |
|---|
| 49 dB(A) | 10 kW model 7257 (7321 with a transfer switch) |
| 55 dB(A) | Newer 14 kW (7258), 18 kW (7259), 20 kW three-phase (7271), 22 kW (7260), 24 kW (72610), 26 kW (7327) and 28 kW (7282); Guardian 14 kW (7223, 7224, 7225) and 18 kW (7226, 7228) |
| 57 dB(A) | Guardian 10 kW (7171, 7172), 22 kW (7042, 7043), 24 kW (7209, 7210) and 26 kW (7290, 7291) |
| 58 dB(A) | Guardian 20 kW three-phase (7077) |
The EcoGen 15 kW (7163) has no exercise figure on its sheet.
How loud is a Generac when it runs in a power outage?
From 61 to 67 dB(A) at normal load, rising with engine size, measured the same way.
| Normal load, 23 ft (7 m), front | Models |
|---|
| 61 dB(A) | 10 kW model 7257, Guardian 10 kW (7171) |
| 65 dB(A) | 14 kW (7258), 18 kW (7259), Guardian 14 kW (7223), Guardian 18 kW (7226) |
| 66 dB(A) | EcoGen 15 kW (7163) |
| 67 dB(A) | Every model of 20 kW and up, newer or Guardian: 7271, 7260, 72610, 7327, 7282, 7077, 7042, 7209, 7290 |
The running figure climbs from 61 at 10 kW to 67 at 20 kW and then stops. A 28 kW model is listed no louder than a 20 kW one.
That leaves one running-noise saving in the whole range short of dropping to 10 kW. If your loads fit an 18 kW unit, it sits 2 dB(A) under the bigger models.
Power Zone models win only in exercise
At normal load every Power Zone and Guardian pair matches. In exercise, the newer model is quieter at most sizes, and the sheets show exactly where.
The biggest gap is at 10 kW: the newer 7257 lists 49 dB(A) in exercise against 57 for the Guardian 7171, 8 dB(A) for $120. At 22, 24 and 26 kW it is 55 against 57, and the newer 20 kW three-phase model lists 55 against 58 for the Guardian 7077. At 14 and 18 kW both lines list 55.
The test itself runs differently. Newer sheets say the generator exercises "for 5 minutes every week" by default, with "a selectable setting for weekly, bi-weekly, or monthly operation with an adjustable run time from 5 to 20 minutes, and an option for a low speed engine rpm". The Guardian 10 to 18 kW sheet describes "running the generator for 5 minutes every other week", with weekly or monthly as options.
Note the word option. The exercise figure is for Quiet-Test low-speed mode, so ask your installer to make sure it is selected.
Smart Exercise, on the newer controller, "Allows the system to skip its scheduled exercise if the generator ran for more than 5 consecutive minutes within the 72 hours prior to a scheduled exercise event". After an outage, that is one test the neighbors never hear.
What is Generac's Quiet-Test mode?
A self-test that runs the engine at a lower RPM, and that lower RPM is what the exercise figures measure. The Guardian product pages say "Quiet-Test™ Self-Test Mode runs at a lower RPM for a five or twelve minute test, making generators significantly quieter than other brands while consuming less fuel."
That comparison with other brands is Generac's, and nobody here has tested it. A maker measuring another side or another load could print a lower number for the same machine, so a Generac front-side 7 meter figure only lines up with another brand's when comparing decibel ratings on the same side and load.
The Guardian sheets also describe "Sound attenuated enclosures" that "ensure quiet operation", and a "Quiet, critical grade muffler" mounted inside the unit. All the air-cooled models have them, which helps explain the narrow band the range sits in.
Protector models are measured at the quietest of 8 points
Generac's residential listing includes the larger Protector models, with liquid-cooled engines, most of which run at 1,800 rpm when delivering power. Their sheets use different rows, "Sound Level at Exercise Speed" and "Sound Level at Operating Speed & No Load", both at 23 ft (7 m). The XG sheets and the 130 and 150 kW sheet add that each figure is the "Lowest sound level measurement of 8 locations around the generator." Position and load both differ from the air-cooled sheets, so these models get separate tables.
| Lowest of 8 points | Exercise speed | No load |
|---|
| XG 25 kW and 30 kW | 51 dB(A) | 59 |
| XG 48 kW | 54 | 58 |
| XG 60 kW and 80 kW | 55 | 64 |
| XG 32 kW and 40 kW | 59 | 66 |
| RG 130 kW | 68 | 72 |
| RG 150 kW | 71 | 77 |
Some Protector sheets give no measuring position at all.
| No position given | Exercise | Running |
|---|
| RG 25 kW and 30 kW at 3,600 rpm | 59 | 72 and 73 at no load |
| Protector QS 22 kW and 27 kW | 61 | 70 |
| RG 100 kW | none | 71 at no load |
| Diesel 15 to 50 kW, one figure for all five sizes | 65 dB(A) in exercise mode | 70 at normal load |
| 30 kW diesel, separate sheet | 65 at exercise speed | 67 at no load |
The XG 25 kW exercises at 1,200 rpm, against 1,800 when running, and lists "Quiet Operation including Selectable Low-Speed Exercise Quiet-Test™" among its features. At $17,199 MSRP and 1,062 lb, though, it is a different class of machine, not a quieter version of an air-cooled unit.
How loud are Generac's portable generators?
Nobody can say from Generac's paperwork, because no current portable gives a dB figure. The lineup covers the GP2500i and GP3300i inverters, the iQ3500, iQ3800 and iQ5200 inverters, the open-frame GP models from 3,600 to 18,000 watts, and the XD5000E diesel, and for each one the linked product page, spec sheet and owner's manual were checked.
Description is what you get instead. The GP2500i sheet calls it "Quiet and Neighbor Friendly" and says its "fully enclosed design dramatically reduces noise levels." On the GP3300i, "Quiet Inverter Power reduces sound emissions and provides optimal performance," and "Economy Mode automatically adjusts engine speed to save fuel and reduce sound emissions." The iQ3800 sheet has "Quiet Operation - Fully enclosed case reduces noise levels" and "Economy Mode - Reduces noise and fuel consumption." Those are fair descriptions of how inverters work.
With no number, distance or load, though, there is nothing to rank.
Buying a Generac portable for quiet means going on those words alone. For portable generators for home backup or small camping inverters with a figure behind them, look to makers that publish one.
Placing the unit with its front away from neighbors
A home standby generator sits beside the house for decades, so the spot deserves the same care as the model. The sheets allow it "as close as 18 in (457 mm) to a structure" but say it "Must be located away from doors, windows, and fresh air intakes and in accordance with local codes."
Every air-cooled figure is taken from the front, so if your installer can, point the front away from the nearest neighbor.
Town noise rules vary, and they are checked at the property line rather than 7 meters from the front of a Generac, so look yours up before the pad is poured. A standby unit is also not the only machine a neighbor hears from your yard.