Are Ruud air conditioners quiet? Their spec sheets say 54 to 76 dBA

Written by
· 9 min read

Ruud air conditioner decibels

Ruud's nine R-454B air conditioners rate 54 to 76 dBA of A-weighted sound power on their spec sheets.

Only the variable speed Ultra UA19AY adds a second, lower row per size, reaching 54 at 4 tons, and among single stage models the 3.5 ton Achiever RA13NY and Choice WA13NY print 68.

On the heat pump side the UP19AY's lower rows of 58 to 60 lead, and the best single row is the RP14AY's 72. Ruud lists no prices.

On this page
  1. How we chose
  2. Our picks
  3. How to choose
  4. Comparison
  5. FAQs
  6. Bottom line
  7. Review history

A quick look at the quietest Ruud air conditioners

54 dBA is the lowest figure on any Ruud air conditioner sheet, and it comes with a catch: it is the lower of two unlabeled rows for the 4 ton Ultra UA19AY. Across the range, Ruud rates its central air conditioners from that 54 up to 76 dBA, on a "Weighted Sound Power Level" table found on page 6 of every spec sheet. The 76 turns up at 5 tons on everything but the two stage UA16AY and the compact WSA14AY.

Ruud is a Rheem Manufacturing brand sold through its own ProPartner contractors, and on November 6, 2026 its comparison guide listed nine R-454B air conditioners and nine heat pumps. Because the numbers match Rheem's, this chart reads alongside our Rheem air conditioner decibels page, only with Ruud's model names, series and paperwork. Heat pumps come later. No Ruud model has a published price.

How we chose these Ruud air conditioners and heat pumps

The starting list was the eighteen R-454B models in Ruud's comparison guide dated 03/26. Each was found on ruud.com's US listings on November 6, 2026 and its spec sheet downloaded, plus the brochure wherever one is quoted. Seventeen had a product page and a sheet with a sound table, and the WSP14AY had neither. The heat pump listing returned a server error on the first try and loaded in full on the next, and every sheet came from Rheem's shared document server, which answered each request.

Air conditioners are ranked apart from heat pumps, two row models apart from one row models, and "as low as" floors not at all. Every figure is Ruud's printed sound power or sound pressure.

QuietSpecs' picks of the quietest Ruud air conditioners

Lowest Ruud AC figure, on an unlabeled row

Ruud Endeavor Line Ultra Series Variable Speed Air Conditioner (UA19AY)

  • Noise: Sound power 54 to 76 dBA in two unlabeled rows, AHRI 270-08 (maker)
  • Price: No maker list price
  • Best for: A 2 to 4 ton system near a bedroom, where a variable speed unit spends long hours well below full output
  • Skip it if: The house needs 5 tons, where even the lower row reads 70

Ruud's only variable speed air conditioner prints two "STANDARD RATING (DBA)" rows per size: "59" and "68" at 2 tons, "57" and "72" at 3, "54" and "72" at 4, "70" and "76" at 5. Which row is which, Ruud never says.

The product page describes cooling "between 40% and 100% of capacity", and at or under 59 from 2 to 4 tons, the lower row is a number no other Ruud AC comes near.

Lowest single stage figure

Ruud Endeavor Line Achiever Series Air Conditioner (RA13NY)

  • Noise: Sound power 68 to 76 dBA, AHRI 270-08 (maker)
  • Price: No maker list price
  • Best for: A northern home that needs 3.5 or 4 tons and is choosing on the sound table
  • Skip it if: Your home sits outside the northern region its listing names

At 3.5 tons the RA13NY42A rates "68" dBA, the lowest one row figure in Ruud's R-454B range, and the 4 ton rates 71. Elsewhere it reads 70 at 1.5 and 2 tons, 71 at 2.5 and 3, and 76 at 5.

The price of that low number is efficiency: 13.4 SEER2, and a listing that says it "Meets energy standards for Northern regions only". Registered, it carries a 10 year conditional parts warranty.

The 2 ton single stage pick

Ruud Endeavor Line Achiever Series Air Conditioner (RA15AY)

  • Noise: Sound power 69 to 76 dBA, AHRI 270-08 (maker)
  • Price: No maker list price
  • Best for: A 2 ton home where efficiency and the sound row both count
  • Skip it if: Your load calculation calls for 3.5 or 4 tons; there the RA13NY reads 5 and 3 dBA lower

On Form No. A22-347 the 2 ton size reads "69" dBA, two under the RA13NY and RA14AY at that size, and the whole row runs 71, 69, 71, 72, 73, 74 and 76 from 1.5 to 5 tons under AHRI 270-08.

The Swept Wing fan, sold on "quieter operation", carries the footnote "Does not apply to 1.5- and 2-ton models", so the 69 comes without it. Ruud's sheet opened where Rheem's twin link was empty in October.

Ruud's two stage air conditioner

Ruud Endeavor Line Achiever Plus Series Two-Stage Air Conditioner (UA16AY)

  • Noise: Sound power 71.9 to 74.1 dBA, AHRI 270-08 (maker)
  • Price: No maker list price
  • Best for: A 5 ton house that values longer, gentler runs and a figure under 76
  • Skip it if: It is a 2 ton job, where the single stage RA15AY lists 69

One figure per size, and the only Ruud AC table with decimals: "74.1" dBA at 2 tons, "71.9" at 3, "73.2" at 4 and "74.0" at 5.

The "Two-Stage Scroll Compressor" has "two speeds (high and low)", but the sheet never says which stage made the number.

The brochure rounds the best of them to "As low as 72 dBA", and at 3 tons that 71.9 still trails the 71 of the RA13NY and RA14AY.

Lowest rated Ruud heat pump

Ruud Endeavor Line Ultra Series Variable Speed Heat Pump (UP19AY)

  • Noise: Sound power 58 to 73 dBA in two unlabeled rows, AHRI 270-08 (maker)
  • Price: No maker list price
  • Best for: A heat pump that runs year round close to bedrooms or a patio
  • Skip it if: Budget points to a two stage unit; the RP14AY rates 72 at 2.5 to 3.5 tons

Two unlabeled rows per size again: "59" and "69" dBA at 2 tons, "60" and "70" at 3, "59" and "73" at 4, "58" and "73" at 5.

The scroll compressor runs "from 40 to 100% capacity", though the full speed range needs EcoNet control, and a Compressor Sound Blanket is standard. Ruud's "As low as 58 dB" headline is the 5 ton lower row.

Lowest single row heat pump figure

Ruud Endeavor Line Achiever Series Heat Pump (RP14AY)

  • Noise: Sound power 72 to 74 dBA, AHRI 270-08 (maker)
  • Price: No maker list price
  • Best for: Buyers whose heat pump load is 2.5 to 3.5 tons and who want a low row without Ultra pricing
  • Skip it if: The UP19AY fits the budget, since its lower rows all sit in the 50s

"72" dBA at 2.5, 3 and 3.5 tons, the lowest one row figures on any Ruud heat pump sheet, with 73 at 1.5 and 2 tons and 74 at 4 and 5.

For a lower tier model, it beats the Achiever Plus RP15AY at three sizes and ties it at the rest. Every size but the 1.5 ton runs a two stage scroll.

How to choose

Ruud's sound power table, size by size

Each sheet closes its table with "Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)". The two digits after the series code give capacity in thousands of Btu per hour: 18 means 1.5 tons, 24 two tons, 36 three, 42 three and a half, 48 four and 60 five.

Model, dBA sound power1.5 tons2 tons2.5 tons3 tons3.5 tons4 tons5 tons
Ultra UA19AY, lower row59575470
Ultra UA19AY, upper row68727276
Achiever Plus UA16AY, two stage74.171.973.274.0
Achiever RA13NY and Choice WA13NY70707171687176
Achiever RA14AY and Choice WA14AY70717171737476
Achiever RA15AY and Choice WA15AY71697172737476
Choice WSA14AY76.076.074.0

A blank cell is a size that model's table does not list. Compressor types differ by line, inverter variable speed on the Ultra, two stage scroll on the Achiever Plus and single stage on Achiever and Choice, and rankings stay inside those groups.

Which Ruud air conditioner is the quietest?

The Ultra UA19AY, if you read its lower row: 54 dBA at 4 tons, and 59 or under from 2 to 4 tons. Nothing else Ruud sells as an air conditioner prints a figure below 68.

The catch sits in the column heading. Both UA19AY rows are labelled "STANDARD RATING (DBA)", and neither gets a speed. A compressor that throttles to 40% ought to spend mild days nearer the bottom row, but on a hot afternoon the upper row, 68 to 76, is the better guide, and at 3 and 4 tons it reads 72.

Among one figure models, tonnage decides. At 1.5 tons the RA13NY, WA13NY, RA14AY and WA14AY share 70, at 2 tons the RA15AY and WA15AY lead with 69, and the RA13NY pair reads 68 at 3.5 tons and 71 at 4. At 5 tons every single stage unit lists 76 and the UA16AY's one figure is 74.0.

Are Ruud and Rheem air conditioners the same?

In their sound tables, yes, figure for figure. The Ultra UA19AY prints the Rheem RA19AY's rows and the Achiever Plus UA16AY the RA16AY's, while the single stage Achiever and Choice units carry the very same model numbers as Rheem's Classic and Select lines. The sheets give the shared origin away. Their form numbers run parallel to Rheem's, A22-345 against A11-345 for the RA13NY, and text pulled from the UA19AY and UA16AY PDFs still holds Rheem model rows hidden behind the printed page.

Where Ruud helps is the paperwork. On October 23, Rheem's RA15AY sheet link returned an empty file, and its WA14AY and WSA14AY links an error. Ruud's equivalents all opened on November 6 and confirm the figures Rheem's product database gave for those three.

Two stages, one printed figure

The two stage UA16AY rates 71.9 to 74.1 dBA, and at 2 tons its 74.1 sits above the RA13NY, RA14AY and RA15AY families, which list 69 to 71. Only the compact WSA14AY, at 76.0, is louder there.

Its sheet promises "two speeds (high and low)" and then publishes one row per size with no word on which speed produced it. If the figure describes the high stage, low stage running should be quieter, but Ruud leaves that unwritten.

It comes out ahead of the single stage models only at 5 tons, where 74.0 undercuts their 76. At 3 tons its 71.9 edges the RA15AY's 72 and trails the RA13NY and RA14AY at 71. On noise grounds alone, that is a thin case for paying for the second stage.

Ruud heat pumps rate 58 to 74 dBA

Five of the nine R-454B heat pumps carry a standard rating table, under the same AHRI 270-08 test.

Three more print only "as low as" columns, and the ninth has no table at all.

Model, dBA sound power1.5 tons2 tons2.5 tons3 tons3.5 tons4 tons5 tons
Ultra UP19AY, lower row59605958
Ultra UP19AY, upper row69707373
Achiever RP14AY and Choice WP14AY73737272727474
Achiever Plus RP15AY and Choice WP15AY73737374747474

No heat pump table says whether a figure is cooling or heating. Our heat pump comparison across brands explains why that gap counts when setting one maker against another.

Which Ruud heat pump is the quietest?

The Ultra UP19AY, with lower rows of 58 to 60 dBA at every size and upper rows, 69 to 73, that also sit below the two stage models at every size.

Among single row heat pumps, the RP14AY and WP14AY lead with 72 at 2.5, 3 and 3.5 tons. The dearer RP15AY never beats them. It ties them at four sizes and reads 73 or 74 where they read 72, and at 5 tons the two rows match band for band, from 43.9 dBA at 125 Hz to 52.9 at 8000 Hz, which suggests the same compressor and fan at that size.

Three heat pump sheets print only floors

The RD18AY, RD16AY and RP17AY sheets give "SOUND PRESSURE AS LOW AS" and "SOUND POWER AS LOW AS" columns instead of a standard rating. These are the quietest each size gets, quoted here and left unranked, and sound pressure depends on a distance none of the three names.

Model, dBA pressure and power2 tons3 tons4 tons5 tons
RD18AY Ultra side discharge53 and 6150 and 5854 and 6155 and 63
RD16AY Achiever Plus side discharge53 and 5950 and 5854 and 6155 and 62
RP17AY Achiever Plus top discharge55 and 6258 and 6458 and 6557 and 64

Ruud advertises both side discharge models with "Quiet Operation as low as 50dBA", which is the 3 ton sound pressure floor. Their 3 and 4 ton rows match down to the octave bands.

Brochure headlines mostly match the tables

Each brochure carries a "Sound Rating" headline credited to "Internal R&D Testing", and for most models it matches the lowest number in the spec sheet table, give or take rounding.

The UA19AY is the exception. Its brochure says "As low as 57 dB", the 3 ton lower row, while the comparison guide, Form No. M22-1100 Rev. 8, says 54 dBA, the 4 ton row. The WSA14AY goes the other way from its Rheem twin: Ruud's "As low as 74 dB" matches its 2.5 ton row of 74.0, and Rheem's product database advertised the same model at 70. Test dates in those footnotes run from "May 2022" on the RA13NY and RP15AY brochures to 2026 on the newest RP17AY one.

Read the headline as a hint, and the row for your own tonnage as the number.

Sound blankets, covers and the Swept Wing fan

A compressor sound blanket or cover comes standard on the UA19AY, UP19AY, RD18AY, RD16AY and RP17AY. On the UA16AY and the Achiever and Choice lines, a "Compressor sound cover" is an accessory, part 68-23427-26 for smaller sizes and 68-23427-25 for larger ones.

The UA19AY's paperwork muddles this. Its standard equipment list includes a "Compressor Sound Blanket", yet its accessory table also offers a "Compressor Sound Cover" as part 686020, and the UP19AY sheet lists that same 686020 as a "Heat Pump Riser 6 in.". Ask the installer which part you are buying.

The Swept Wing fan, credited with "quieter operation and improved unit acoustics", appears on the Ultra and Achiever Plus sheets and on the RA14AY and RA15AY, though not at 1.5 and 2 tons. No sheet says what it saves in decibels.

Models with no sound table, and older R-410A units

One R-454B model in the comparison guide has no table we could find. The WSP14AY heat pump is credited there with a 73 dBA "as low as" rating but is missing from the ruud.com heat pump listing, which shows only its R-410A sibling, the WSP14AZ.

The listings also still carry older R-410A units, coded AZ or NZ: the UA18AZ, UA16AZ, RA15AZ, RA14AZ, RA13NZ and WA15AZ air conditioners and the UP18AZ, RP15AZ and RP14AZ heat pumps among them. The 03/26 comparison guide leaves them all out, and so does this page.

None of the R-454B models is marked discontinued, though one is misfiled: the air conditioner listing titles the WSA14AY a "Heat Pump" and prints a heating efficiency, while its spec sheet heads it "Air Conditioners".

How the quietest Ruud air conditioners compare

ProductNoiseCompressorSeriesSizesSEER2Price
Ruud UA19AYSound power 54 to 76 dBA in two unlabeled rows, AHRI 270-08 (maker)Variable speed inverter, 40 to 100%Endeavor Line Ultra, iM cabinet2 to 5 tonsUp to 20.0Not verified yet
Ruud RA13NYSound power 68 to 76 dBA, AHRI 270-08 (maker)Single stageEndeavor Line Achiever, iM cabinet1.5 to 5 tons13.4Not verified yet
Ruud RA15AYSound power 69 to 76 dBA, AHRI 270-08 (maker)Single stage scrollEndeavor Line Achiever, iM cabinet1.5 to 5 tonsUp to 16.0Not verified yet
Ruud UA16AYSound power 71.9 to 74.1 dBA, AHRI 270-08 (maker)Two stage scrollEndeavor Line Achiever Plus, iM cabinet2 to 5 tonsUp to 17Not verified yet
Ruud UP19AYSound power 58 to 73 dBA in two unlabeled rows, AHRI 270-08 (maker)Variable speed scroll, 40 to 100%Endeavor Line Ultra, iM cabinet2 to 5 tonsUp to 20.0Not verified yet
Ruud RP14AYSound power 72 to 74 dBA, AHRI 270-08 (maker)Two stage scroll, 1 stage at 1.5 tonsEndeavor Line Achiever, iM cabinet1.5 to 5 tonsUp to 15.2Not verified yet

Frequently asked questions

How many decibels is a Ruud air conditioner?

54 to 76 dBA of sound power, by Ruud's spec sheets. The variable speed UA19AY covers that whole span across its two rows, the two stage UA16AY reads 71.9 to 74.1, and single stage Achiever and Choice models run 68 to 76. Every table cites AHRI Standard 270-08.

What is the quietest Ruud air conditioner?

The Ultra UA19AY, whose lower row reads 54 dBA at 4 tons. Among models with one figure per size, the RA13NY and WA13NY reach 68 at 3.5 tons. The UA19AY's rows carry no labels, so those two answers describe different things and are not ranked against each other.

Is a Ruud heat pump louder than a Ruud air conditioner?

It depends on size. The two stage RP14AY and RP15AY heat pumps rate 72 to 74 dBA, level with or above the single stage Achiever air conditioners from 1.5 to 4 tons, which list 68 to 74, and below them at 5 tons, where they list 76. At the top end, the UP19AY heat pump's lower rows of 58 to 60 sit level with or above the UA19AY air conditioner's 54 to 59 from 2 to 4 tons.

Are Ruud Choice models louder than Achiever models?

No. Every Choice air conditioner and heat pump prints an Achiever model's sound table: WA13NY matches RA13NY, WA14AY matches RA14AY, WA15AY matches RA15AY, WP14AY matches RP14AY and WP15AY matches RP15AY. The louvered iC cabinet and some efficiency ratings are what differ.

What does dBA mean on a Ruud spec sheet?

A-weighted sound power, a measure of everything the condenser radiates, rated under AHRI Standard 270-08 with no distance attached. Three side and top discharge heat pump sheets add a sound pressure column, which depends on distance, and the two kinds of figure cannot be compared. The reason is set out in our sound power explainer.

The bottom line

Of the two Rheem brands, Ruud is the easier one to research. Every R-454B condenser on ruud.com links a spec sheet that opens, with a size by size sound table on page 6. That includes three models whose Rheem twins gave me an empty file or an error last month.

If you know Rheem's tables, these hold no surprises. Same compressors, same numbers.

Size is what I would act on. At 3.5 tons, the RA13NY's 68 dBA beats Ruud's dearer single stage units. For a heat pump, get a dealer's price on the UP19AY before settling for a two stage RP14AY at 72 to 74.

Stanley Alu, founder and editor

What we also considered

These are worth knowing about, and why they didn't make the list.

  • Ruud Endeavor Line Achiever Series Air Conditioner (RA14AY)

    A row of 70 to 76 dBA that ties the RA13NY at 1.5 tons and never leads alone; at 4 tons it reads 74 against the RA13NY's 71.

    Search Amazon for this model
  • Ruud Endeavor Line Choice Series Air Conditioner (WA13NY)

    The louvered Choice twin of the RA13NY: 68 dBA at 3.5 tons, identical octave bands, and the same northern only listing.

    Search Amazon for this model
  • Ruud Endeavor Line Choice Series Air Conditioner (WA15AY)

    Same 71 to 76 row as the RA15AY, 69 at 2 tons included, in the iC cabinet at 15.2 SEER2 instead of 16.0.

    Search Amazon for this model
  • Ruud Endeavor Line Choice Series Air Conditioner (WA14AY)

    A size for size copy of the RA14AY table, 70 dBA at 1.5 tons up to 76 at 5.

    Search Amazon for this model
  • Ruud Endeavor Line Choice Series Compact Air Conditioner (WSA14AY)

    Stops at 2.5 tons and rates "76.0" at 1.5 and 2 tons and "74.0" at 2.5, the loudest small sizes Ruud prints.

    Search Amazon for this model
  • Ruud Endeavor Line Achiever Plus Series Two-Stage Heat Pump (RP15AY)

    Two stage, 73 to 74 dBA, and never quieter than the cheaper RP14AY, whose 5 ton octave bands it matches exactly.

    Search Amazon for this model
  • Ruud Endeavor Line Choice Series Two-Stage Heat Pump (WP15AY)

    The RP15AY in a Choice cabinet, with the same 73 to 74 dBA row.

    Search Amazon for this model
  • Ruud Endeavor Line Choice Series Heat Pump (WP14AY)

    The RP14AY table, 72 at 2.5 to 3.5 tons, in the louvered iC cabinet.

    Search Amazon for this model
  • Ruud Endeavor Line Ultra Series Side-Discharge Universal Heat Pump (RD18AY)

    Only "AS LOW AS" columns on this side discharge Ultra, 58 to 63 dBA sound power and 50 to 55 sound pressure, so it is quoted but not ranked.

    Search Amazon for this model
  • Ruud Endeavor Line Achiever Plus Series Side-Discharge Heat Pump (RD16AY)

    Floors again: its "AS LOW AS" columns copy the RD18AY at 3 and 4 tons and read 59 and 62 dBA sound power at 2 and 5.

    Search Amazon for this model
  • Ruud Endeavor Line Achiever Plus Series Top-Discharge Universal Heat Pump (RP17AY)

    A top discharge variable speed heat pump whose sound power reads "AS LOW AS" 62 to 65 dBA and sound pressure 55 to 58, floors that stay unranked.

    Search Amazon for this model

How we reviewed this article

Every statement here comes from the 25 maker documents, standards and agency pages listed under Sources, quoted where the wording matters. We did not measure, inspect or repair anything ourselves. Each substantive revision is dated below. How we work

  1. Current version

    First published, written by Stanley Alu.

Sources

All 25 sources