An NRC rating, short for noise reduction coefficient, is one number for how much sound a material absorbs instead of reflecting back into the room, averaged across four frequencies in a laboratory test. Higher means more absorption. Ceiling tiles, acoustic panels, insulation boards and even theater drapes carry one.
It describes sound inside a space, not noise passing through a wall, floor or ceiling into the next room.
What does an NRC rating mean?
An NRC rating condenses a material's sound absorption coefficients into a single figure for comparing products. ASTM's summary of its C423 test method describes the coefficient, in its ideal form, as the fraction of randomly arriving sound power that a surface absorbs.
The test happens in a reverberation room, where the lab works out absorption from the rate at which sound decays around a specimen such as acoustical ceiling tile. ASTM's summary also warns that the coefficients deserve caution in real buildings, since real surfaces are usually larger than the sample and real rooms rarely spread sound evenly in every direction.
Armstrong, the ceiling maker, describes NRC in its acoustical design guide as a rating for the overall absorption of a material installed inside a building, where sound strikes surfaces "at various angles of incidence." Its residential store's glossary keeps it shorter: "How a tile's ability to absorb sound is measured."
The coefficient behind it has a nominal range. Rockfon's acoustics FAQ puts it this way: "Zero represents no absorption (total reflection), and 1.00 represents total absorption of the incident sound." Printed NRC values often run past 1.00 anyway.
How is the noise reduction coefficient calculated?
The noise reduction coefficient is the average of four absorption coefficients, measured at 250, 500, 1000 and 2000 Hz, rounded to the nearest 0.05. Accredited lab reports print the definition word for word.
Riverbank Acoustical Laboratories, accredited under the NIST-run NVLAP program, words it this way in a 2018 report for Primacoustic: NRC is "defined from previous versions of this same test method as the average of the coefficients at 250, 500, 1000, and 2000 Hz, expressed to the nearest integral multiple of 0.05."
That report, RAL-A18-071, makes a clean worked example. The sample was a 2 inch Hercules panel laid directly against the test surface, the arrangement called Type A mounting.
| Frequency | Coefficient in the report |
|---|---|
| 250 Hz | 0.87 |
| 500 Hz | 1.05 |
| 1000 Hz | 1.00 |
| 2000 Hz | 0.97 |
| Average of the four (our arithmetic) | 0.9725 |
| NRC as printed | 0.95 |
The four bands add up to 3.89, and a quarter of that is 0.9725. On a grid of 0.05 steps, the nearest value is 0.95, which is what Riverbank printed. The same report gives an SAA of 0.97, closer to the raw average because that figure rounds to the nearest 0.01.
Where SAA fits beside NRC
SAA, the sound absorption average, is a second single number from the same C423 test: it averages twelve one-third octave bands from 200 to 2500 Hz and rounds to 0.01 instead of 0.05.
A 2020 Riverbank report for Auralex cites the source of each definition. SAA is "defined in ASTM C423-17 Section 3.1.1", while NRC "is defined from previous versions of ASTM C423." Read together, the newer edition defines SAA and the reports still carry NRC forward from earlier ones. Neither report calls NRC withdrawn, and both print it on the results page.
In practice the two land close together. Across these four published test results, the gap is never more than 0.02:
| Product | NRC | SAA |
|---|---|---|
| Primacoustic Hercules, 2 in. | 0.95 | 0.97 |
| Auralex Studiofoam Royale, 75 mm | 1.05 | 1.05 |
| Rose Brand Encore velour drape | 1.00 | 0.99 |
| ROCKWOOL Safe'n'Sound, 3 in. | 1.10 | 1.11 |
The GSA's 2018 facilities standard accepts either, heading its ceiling and wall absorption columns "SAA/NRC".
Can an NRC rating be above 1?
Yes. NRC values above 1.0 are common for thick, highly absorptive products, because the reverberation room test credits a sample for sound that bends around its exposed edges.
The cause is the sample's edges, which bend sound into it so it behaves like a bigger patch than it is. A 2015 conference paper by NASA Glenn Research Center engineers and Riverbank staff studied the effect on acoustic foam. They found the measured Sabine coefficients "are greater than 1.0 for highly absorptive materials," because edge diffraction makes "its acoustic footprint" larger than the real surface. Smaller specimens produced bigger values, and the effect was stronger at low frequencies.
Their summary draws the key distinction. The Sabine coefficient from the reverberation room "is not the same as the acoustic Energy Absorption Coefficient," the ratio of absorbed to incident energy, which "cannot exceed 1.0."
That is why this page does not convert an NRC into a percentage of sound absorbed. None of the primary sources we opened makes that conversion, and a rating of 1.25 could not be one.
Values above 1 turn up across makers:
- Owens Corning lists 703 board at NRC 1.15 in both 3 and 4 inch thicknesses.
- ROCKWOOL lists 6 inch Safe'n'Sound at NRC 1.25 and SAA 1.25.
- Armstrong's SoundScapes Blades, 10 inches deep at 6 inch spacing, reach NRC 1.15.
- Auralex Studiofoam Royale tested at NRC 1.05.
European data show the contrast. On Rockfon's Industrial Nature page, the ISO practical coefficients read 1.00 from 500 Hz up and the weighted figure αw is 1.00, yet the same panel carries an NRC of 1.05.
NRC values for common materials and products
Published NRC values run from 0.05 for a plain drywall ceiling to 1.25 for a 6 inch stone wool batt, and each one depends on the thickness and mounting in the test.
| Material or product | Size or setup | NRC | Test and mounting |
|---|---|---|---|
| Drywall ceiling (Armstrong room example) | Untreated | 0.05 | Not stated |
| Carpet on concrete (CRI tests) | Various piles | .15 to .55 | ASTM C423 |
| Armstrong Designer 734 ceiling tile | 24 x 48 x 5/8 in. | 0.55 | Armstrong product page |
| Owens Corning 703 board | 1 in. | 0.70 | C423, Type A |
| Armstrong Cirrus High NRC ceiling panel | Suspended ceiling panel | 0.75 | C423, E-400 |
| Primacoustic Hercules panel | 2 in. | 0.95 | C423-17, Type A |
| Owens Corning 703 board | 2 in. | 1.00 | C423, Type A |
| Rose Brand Encore velour drape | 100% fullness | 1.00 | C423-09a, Type G-100 |
| Auralex Studiofoam Royale | 75 mm | 1.05 | C423-17, Type A |
| ROCKWOOL Safe'n'Sound batt | 3 in. | 1.10 | C423, mounting not stated |
| ROCKWOOL Safe'n'Sound batt | 6 in. | 1.25 | C423, mounting not stated |
The Designer 734 tile is a 24 by 48 inch square-edged lay-in tile. Its 0.55 clears Armstrong's low performance line of 0.50 but not its high performance line of 0.70.
The Rose Brand drape is heavy stage velour, tested hanging 4 inches from the chamber wall. It is not a typical living room curtain. We found no maker of home blackout or "noise reducing" curtains that publishes a C423 NRC.
Bare building surfaces barely register. The UK government's Approved Document E, its guidance on sound in homes, prints typical coefficients for common finishes. These are octave band coefficients, not NRCs:
| Surface (Table 7.1) | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz |
|---|---|---|---|---|
| Fair-faced concrete or plastered masonry | 0.01 | 0.01 | 0.02 | 0.02 |
| Painted concrete block | 0.05 | 0.06 | 0.07 | 0.09 |
| Windows, glass facade | 0.08 | 0.05 | 0.04 | 0.03 |
| Timber doors | 0.10 | 0.08 | 0.08 | 0.08 |
| Hard floor such as lino or parquet on concrete | 0.03 | 0.04 | 0.05 | 0.05 |
| Carpet on concrete | 0.03 | 0.06 | 0.15 | 0.30 |
| Suspended plasterboard ceiling, large void | 0.15 | 0.10 | 0.05 | 0.05 |
Averaged over the four NRC bands, by our arithmetic, none reaches 0.15. Carpet on concrete comes to 0.135 and plastered masonry to 0.015.
Carpet, cushion and underlay
Carpet absorbs the most of the finishes in that table, and the Carpet and Rug Institute's bulletin, revised in 2018, reports a test program to ASTM C423. Carpet laid directly on concrete "had NRCs ranging between .15 and .55." Loop pile averaged .20 to .35, and cut pile scored higher than loop pile of otherwise identical construction.
What sits underneath counts for a lot. A 40 ounce per square yard hair cushion raised the NRC by .10 to .20. In one series, a loop carpet rated .35 on the bare floor reached .60 over an 86 ounce hair cushion. A sponge rubber cushion bonded to the carpet produced "an NRC of only .30," and the bulletin names permeability "the most critical construction factor." We did not find a rug pad maker publishing an NRC for its own pads.
What is a good NRC rating?
A good NRC rating depends on the room. Armstrong's ceiling glossary calls a ceiling "NRC < .50" low performance and "NRC > .70" high performance, and U.S. federal building specs ask for 0.70 to 0.90.
| Source | Space | NRC asked for |
|---|---|---|
| Armstrong glossary | Any ceiling | Under .50 low, over .70 high |
| UFGS 09 51 00 (2020) | Rooms normally occupied | 0.70 minimum |
| UFGS 09 51 00 | Enclosed rooms with several people or noisy equipment | 0.80 minimum |
| UFGS 09 51 00 | Open areas, especially high density | 0.90 minimum |
| GSA Sound Matters (2011) | Open plan offices | 0.9 minimum |
| GSA Sound Matters | Meeting rooms and training facilities | 0.8 minimum |
| GSA P100 (2018) | Open plan offices without sound masking | 0.9 over 100% of the ceiling |
| GSA P100 | Child care centers | 0.8 over 80% of the ceiling |
The UFGS 09 51 00 ceiling spec, shared by the Army Corps of Engineers, the Navy and the Air Force, explains when NRC is the right yardstick. It is "used when the concern is general reverberation, loud occupant noise levels or speech intelligibility inside enclosed rooms."
The GSA rows come from Sound Matters, a 2011 office guide, and the 2018 P100, which the agency's lighting and acoustics Q and A says its Core Building Standards have since replaced.
None of this is a rule for houses. These are specs for federal offices and military buildings plus one maker's scale, and we found no U.S. code that sets an NRC for a home.
Mounting and thickness move the number
The same product can earn two different NRCs depending on how it was mounted in the test. ASTM's E795 summary states that absorption depends on how a material sits over a surface, so its mountings aim to copy normal use, and reports may name a mounting by its type code alone.
Type A is the simplest. Owens Corning's sheet defines it as "Material placed against a solid backing." Suspended ceilings are tested in Type E-400, the designation on Armstrong's tables and in the federal ceiling spec.
Armstrong's UL acoustical summary lists one product two ways. Lyra Direct Apply panels glued to a surface, A-Mount, rate NRC 0.80. Fixed in the D-40 mounting, the same panels rate 1.00.
Depth and spacing count too. Armstrong's blades range from NRC 0.30, 5 inches deep at 24 inch spacing, to 1.15 at 10 inches deep and 6 inch spacing.
The panel maker Troldtekt, which tests to ISO 354 and prints an NRC beside the ISO figures, shows the biggest swing. Its 25 mm fine structure panel fixed straight to concrete rates NRC 0.55; with 95 mm of mineral wool behind it, the same panel rates 1.00.
Ecophon's guidance is blunt about this: "Sound absorption figures without corresponding o.d.s. are inconclusive and can't be used for comparison." O.d.s. stands for overall depth of system. When comparing two products, check that both NRCs come from the same mounting.
What an NRC leaves out
An NRC ignores everything below 250 Hz and above 2000 Hz, so two materials with identical ratings can behave very differently on bass and on hiss. Owens Corning's own sheet shows it.
| Owens Corning 1 inch board | 125 Hz | 250 Hz | 2000 Hz | 4000 Hz | NRC |
|---|---|---|---|---|---|
| 703 Unfaced | 0.05 | 0.26 | 0.97 | 0.94 | 0.70 |
| 703 FRK | 0.14 | 0.71 | 0.47 | 0.21 | 0.70 |
Both rate 0.70. The unfaced board is weak at 250 Hz and strong at the top; the FRK version reverses the pattern. And at 125 Hz, just under the NRC range, the unfaced 1 inch board absorbs almost nothing, while 4 inches of the same board reaches 0.56.
Rockfon makes a similar point in its FAQ: "NRC gives equal weighting across the frequency range," which it says makes it less accurate than αw, the European rating. Approved Document E's detailed calculation, Method B, skips single numbers and checks absorption in every octave band from 250 to 4000 Hz.
For low-pitched sound, the 125 and 250 Hz columns on a data sheet say more than the NRC does.
NRC, αw and absorption classes outside the US
Europe rates absorbers with αw, the weighted sound absorption coefficient, and absorption classes A to E, both worked out under ISO 11654 from reverberation room data measured to ISO 354.
ISO 354 covers measuring "the sound absorption coefficient of acoustical materials used as wall or ceiling treatments," plus objects such as furniture and people. ISO 11654, first published in 1997, was last reviewed and confirmed in 2023. Rockfon describes the method: αw "is calculated in accordance with ISO 11654 using the practical sound absorption coefficient αp values at standard frequencies and comparing them with a reference curve."
The classes are coarse. Rockfon calls them "only a rough indicator of sound absorption," and Ecophon notes that class A has the highest absorption. We have not printed the class boundaries here, because no primary page we could open states them.
αw and NRC do not convert one to one. In Troldtekt's tables, an αw of 0.95 sits beside an NRC of 1.05 for one panel and 1.00 for another, and αw 0.35 pairs with NRC 0.55.
The UK uses the classes in its building rules. Requirement E3 of Approved Document E covers corridors and halls in blocks of flats, and its Method A asks builders to cover an area at least equal to the floor "with a Class C absorber or better."
Why a high NRC does not stop noise from next door
NRC measures what a surface soaks up, not what it stops from passing through. Armstrong's design guide puts this under a heading of its own, "Sound Absorption is not a Substitute for Sound Blocking," and says high-NRC ceilings "cannot block sound from leaving or entering the space."
For ceilings, the blocking rating is CAC, the ceiling attenuation class. Armstrong defines it as a measure of a ceiling "as a barrier to airborne sound transmission through a common plenum between adjacent closed spaces." Its UL summary shows the trade-off inside one tile family:
| Armstrong Cirrus tile | NRC | CAC |
|---|---|---|
| Cirrus High NRC | 0.75 | 35 |
| Cirrus High CAC | 0.70 | 40 |
The federal ceiling spec sees the same tension across the market: "Limited acoustical ceiling panels can achieve CAC rating above 40 and these panels often do not comply with the specified sound absorption ratings."
Insulation adds a twist. ROCKWOOL sells Safe'n'Sound for walls and floors, yet its data sheet prints an absorption NRC of 1.10 for the 3 inch batt. That number describes the batt in a reverberation room, not the wall it ends up in. For blocking between rooms, the rating to read is STC, and our STC rating page lays out how wall assemblies score.
What absorption changes in a room
Absorption shortens how long sound lingers, which is what makes a bare room feel loud. Armstrong's guide gives an example. A room with a drywall ceiling, NRC 0.05, has a reverberation time of 2.05 seconds. An Ultima acoustical ceiling brings that down to 0.49 seconds. Adding two walls of Soundsoak 60 panels, NRC 0.60, takes it to 0.26 seconds.
Kanopi's glossary describes the effect in plain terms: reverberation "depends on both the volume of the room and the amount of installed sound absorption, so small hard surfaced rooms feel louder than large well-treated rooms."
Absorption does not change what a machine emits. A maker's sound power figure stays the same in any room, while the level you hear depends on the space around it, the split explained in sound power vs sound pressure. A projector in a small room with hard walls, or a desktop PC in a tiled study, sits in the kind of room Kanopi describes. Our projector guide ranks the machines by their published figures; the room is a separate variable.
The quiet home office and quiet bedroom guides cover what each appliance publishes, and the decibel chart puts those levels in context.
NRC is not NRR
The two acronyms differ by one letter and describe unrelated things. NRR, the noise reduction rating, is defined in 40 CFR 211.203 as "a single number noise reduction factor in decibels" for hearing protectors.
So an NRR is measured in decibels and printed on earplugs and earmuffs. An NRC has no unit and is printed on ceiling tiles, panels and insulation. Our NRR page covers how the earplug rating is tested and derated.
How this page was sourced
NRC and SAA definitions come from Riverbank lab reports published by Primacoustic and Auralex; test and mounting background comes from ASTM's public summary pages for C423 and E795. The explanation of values above 1.0 comes from the 2015 NASA conference paper. Product ratings are quoted as published by the makers and the Carpet and Rug Institute. Recommended minimums come from UFGS 09 51 00 and two GSA documents; UK surface data and absorber classes come from Approved Document E. ISO 354 and ISO 11654 were read through Internet Archive copies of the ISO pages. We did not measure any material.