Free noise exposure calculator: pick a tool or type a dBA level to see the safe minutes per day under NIOSH and OSHA, and what earplugs or earmuffs really take off.

Key takeaways

  • Under the NIOSH recommended limit, 85 dBA is allowed for 8 hours and each 3 dB above it halves the time: a tool at 94 dBA uses up the whole day in 60 minutes.
  • OSHA, the legal limit for US workplaces, starts at 90 dBA and halves every 5 dB, so it allows far longer at the same level: 5 hours 17 minutes at 93 dBA against 1 hour 16 minutes from NIOSH.
  • The NRR on a box of earplugs overstates real protection. OSHA estimates field protection by taking 7 dB off the NRR and halving what is left, so NRR 29 earplugs count for about 11 dB.
  • Wearing earplugs under earmuffs adds only about 5 dB on top of the better of the two, per the OSHA technical manual.
On this page
  1. Work out your safe time
  2. How the calculator gets the time
  3. What do earplugs and earmuffs really take off?
  4. Which number from the manual belongs here?
  5. What makers publish
  6. FAQs
  7. How we reviewed this article

Pick a tool or type a level, and the calculator below gives the time per day you can spend at it before the dose reaches the NIOSH limit. It also shows OSHA's looser workplace allowance, and what a pair of earplugs or earmuffs changes once its label is discounted the way OSHA does it. The tools in the list carry their makers' own declared levels at the operator, quoted with the standard each maker used.

The arithmetic is short.

Every 3 dB above 85 dBA halves the safe time, which is why a hedge trimmer at 97 dBA is good for half an hour and a chainsaw at 99 dBA for less than twenty minutes.

Work out your safe time

Choose a tool from the list or type your own reading in dBA, then enter how long you expect to run it today. Add hearing protection and its NRR, the Noise Reduction Rating printed on the package, to see the level that is likely to reach your ear.

Safe time per day at a noise level

NIOSH's recommended limit allows 1 hour a day at 94 dBA. Your 30 minutes uses 50% of that daily dose.OSHA's legal limit for workplaces is looser: 4 hours 36 minutes at the same level.

All noise in one day adds up. The protection estimate halves the NRR after OSHA's 7 dB correction; a poor fit protects less.

How the calculator gets the time

NIOSH, the federal research institute for workplace safety, recommends an exposure limit of 85 dBA averaged over 8 hours and an exchange rate of 3 dB, set out in its criteria document. Each 3 dB step doubles the sound energy, so the allowed time halves with every step: 4 hours at 88 dBA, 1 hour at 94, 15 minutes at 100. In one line, the minutes allowed equal 480 divided by 2 to the power of (level minus 85) divided by 3.

OSHA's enforceable limit uses the same shape with different numbers: 90 dBA for 8 hours and a 5 dB exchange rate, from the noise exposure computation OSHA publishes as Appendix A to its noise standard. The gap between the two grows with the level. At 93 dBA, the declared figure for Bosch's GCM12SD miter saw, NIOSH allows 1 hour 16 minutes and OSHA 5 hours 17 minutes.

The result leads with NIOSH because its limit is the more protective one. OSHA's noise page quotes the NIOSH allowance at 100 dBA beside its own.

The time is a daily budget, shared by everything loud you do that day. The dose percentage in the result is your planned minutes divided by the minutes allowed. Run two tools and add their percentages; the total should stay under 100. A morning on the miter saw at 93 dBA for 38 minutes is half a day's dose on its own, and half an hour with a hedge trimmer declared at 97 dBA after lunch spends the other half, which leaves nothing for the leaf blower at the end of the afternoon even though no single job felt long.

What do earplugs and earmuffs really take off?

Less than the box says.

The NRR comes from a laboratory fit with trained subjects, and the OSHA technical manual gives a method for estimating what a worker actually gets when only A-weighted levels are known. Subtract 7 dB from the NRR to correct for the weighting, then apply a 50% safety factor to what remains.

The calculator uses that method. NRR 29 foam earplugs become (29 minus 7) times one half, about 11 dB. Against a 94 dBA blower that leaves roughly 83 dBA at the ear, and the safe time rises from 1 hour to more than 12.

Doubling up helps less than intuition suggests. For earplugs under earmuffs, the manual takes the higher of the two NRRs, applies the same correction, and adds 5 dB for the second protector. NRR 29 plugs under NRR 25 muffs therefore count for about 16 dB, enough to bring a 99 dBA chainsaw down to roughly 83.

NIOSH's criteria document derates labels by type instead: 25% off for earmuffs, 50% for formable foam plugs, 70% for other earplugs. Either way, fit matters more than the number. A plug that is not rolled and seated deep in the canal can lose most of its rating.

Which number from the manual belongs here?

The sound pressure at the operator's position. European manuals print it as LpA or Lpeq, with an uncertainty K beside it, and the tools in the calculator's list are declared that way. Our guide to power tool noise and hearing explains how to find the line in a manual.

Two other figures look similar and do not belong here. Sound power, LwA, is the tool's total output and always reads higher than the level at your ear. The sound power page goes through why. A US leaf blower rating taken 50 feet away is for the neighbors, and typing it in would make a blower look far safer to its operator than it is. To see what a machine sounds like next door, use the noise distance calculator instead.

A declared level is a lab result for one task. Real work with a dull blade, a different material or a worn tool can run several decibels higher, so treat the safe time as an upper bound and wear protection whenever a tool's own manual tells you to.

What makers publish

The noise figures makers print for models in our buying guides, word for word, with any setting or distance they give. Figures taken under different conditions are not comparable, so this list does not rank them.

The quietest leaf blowers, ranked on the 50 ft rating

ModelNoise figure, as published
STIHL BGA 30 Battery Blower Set (AS System, 2x AS 2 batteries, AL 1 charger)50 dB(A) at 15 m, ANSI/OPEI B175.2 (maker)
M18 FUEL Blower (Tool Only)54 dB(A) at 50 ft, ANSI B175.2 (maker)
BGA 50 Battery Powered Blower (BGA 50 Set w/ AK 20 battery & AL 101 charger)55 dB(A) at 15 m, ANSI B175.2 (maker)
18V LXT Lithium-Ion Brushless Cordless Blower Kit (4.0Ah)60 dB(A), ANSI B175.2 (maker)
40V max XGT Brushless Backpack Blower, Tool Only60 dB(A), ANSI B175.2 (maker)

All 8 models in the guide

The quietest string trimmers

ModelNoise figure, as published
STIHL FSA 57 Battery Grass Trimmer (AK System)"LpA measured according to EN 50636-2-91: 74 dB(A)", K 2 dB(A) (maker manual)
Husqvarna 520iLX Battery String Trimmer (Tool Only)"Sound pressure level at operators ear 76 dB(A)" (maker US page)
EGO POWER+ ST1511T 15-Inch POWERLOAD String Trimmer, Telescopic Aluminum Shaft (Kit)"LPA 78.1 dB(A), K=3 dB(A)" (maker EU manual for ST1510E-T)
STIHL FSA 86 R Battery Grass Trimmer (AP System)"LpA measured as specified in EN 50636-2-91: 77 dB(A)", K 2 dB(A) (maker manual)

The quietest hedge trimmers

ModelNoise figure, as published
STIHL HSA 100 Battery Hedge Trimmer (AP System)"Lp measured according to EN 62841-4-2: 76 dB(A)", K 2 dB(A) (maker manual)
STIHL HSA 60 Battery Hedge Trimmer (AK System)"Lp measured according to EN 62841-4-2: 77 dB(A)", K 2 dB(A) (maker manual)
Husqvarna 115iHD55 Battery Hedge Trimmer"Sound pressure level at operators ear" 78 dB(A) (maker US page)
STIHL HSA 26 Battery Shrub Shear (AS System)"LpA measured as specified in EN 62841-4-2: 72 dB(A)", K 2 dB(A) (maker manual)
EGO POWER+ HT2500 25 inch Hedge Trimmer"Sound pressure level at operator's position LPA" 83.45 dB(A) (maker EU manual for HT6500E)

The quietest chainsaws

ModelNoise figure, as published
STIHL MSA 60 C-B Battery Chainsaw (AK System)"LpA measured according to EN 62841-4-1: 83 dB(A)", K 2 dB(A) (maker manual)
Husqvarna 225i Power Axe Battery Chainsaw (Battery and Charger Included)"Sound pressure level at operators ear" 89 dB(A) (maker US page)
Husqvarna Power Axe 350i Battery Chainsaw (Tool Only)"Sound pressure level at operators ear" 91 dB(A) (maker US page)
EGO POWER+ CS1611 16-Inch Battery Chainsaw (Kit)"Sound pressure level at operator's ear LPA" 91.25 dB(A), K 2.5 dB(A) (maker EU manual for CS1610E)
STIHL MSA 190 T Top Handle Battery Chainsaw"LpA measured according to EN 62841-4-1: 91 dB(A)", K 2 dB(A) (maker manual)

Frequently asked questions

How long can you be exposed to 100 dB?

About 15 minutes a day under the NIOSH recommended limit, which halves the 8 hour allowance at 85 dBA for every 3 dB. OSHA's workplace rule allows 2 hours at 100 dBA because it starts at 90 dBA and halves every 5 dB. The calculator above gives the same answers for any level.

Is 85 dB safe for 8 hours?

It is the edge of the NIOSH recommendation, not a comfortable margin. NIOSH treats 85 dBA averaged over 8 hours as the point where exposure becomes hazardous, and still puts the excess risk of hearing loss at 8% for workers exposed there across a 40 year career.

How much does an NRR 33 earplug really reduce noise?

Less than 33 dB in practice. Using OSHA's field method for A-weighted levels, subtract 7 and halve the rest: an NRR 33 earplug counts for about 13 dB. A poor fit or a break in the seal lowers that further.

Does wearing earplugs and earmuffs together double the protection?

No. The OSHA technical manual adds 5 dB to the field value of the higher-rated protector, so NRR 29 earplugs under NRR 25 earmuffs count for about 16 dB, not 22 or more.

Which number from a tool manual should I enter?

The sound pressure at the operator, usually printed as LpA or Lpeq next to an uncertainty K. A sound power figure (LwA) or a leaf blower's rating at 50 feet describes something else and will understate or overstate what reaches your ears.

How we reviewed this article

Every statement here comes from the 5 maker documents, standards and agency pages listed under Sources, quoted where the wording matters. We did not measure, inspect or repair anything ourselves. Each substantive revision is dated below. How we work

  1. Current version

    First published, written by Stanley Alu.

Sources

Written by

Stanley Alu

Founder and editor

I founded QuietSpecs after running a product review blog, and I built it around the spec that is hardest to pin down. With noise, makers tend to quote the quietest setting they can find, or nothing at all. So I read the spec sheets, manuals and certification directories, quote each figure with the setting it describes, and say so plainly when a maker publishes none. I do not test products or measure decibels, and no brand pays for a place in a guide.

How we compare products

Related buying guides

More in Noise Basics