PTAC making noise? Pinging, clicking, fan cycling and defrost sounds explained

Written by · Checked against 6 sources
· 13 min read

A PTAC that pings or trickles is throwing condensate at its outdoor coil, and a click is a relay or the thermostat. What GE, Hotpoint, Amana, Friedrich and GREE manuals call normal, and the rattles, rapid cycling and smells they flag.

Key takeaways

  • Friedrich, GREE and Hotpoint print the same verdict in their troubleshooting tables: clicking, gurgling and whooshing during operation are normal.
  • Pinging and trickling come from the outdoor fan picking up condensate from the base pan and throwing it on the coil, a feature GE, Amana and Friedrich say raises efficiency.
  • A fan that stops and starts with the compressor is a setting. GE calls it Smart Fan, Amana a fan cycle switch, and Friedrich and GREE offer a constant fan option.
  • Amana warns that air blocked or bounced back into the unit can make the compressor cycle on and off rapidly, and asks for at least eight inches of clearance in front.
On this page
  1. Why is my PTAC making noise?
  2. Which PTAC sounds do the makers call normal?
  3. Why does my PTAC sound like water splashing or pinging?
  4. Why is my PTAC unit clicking?
  5. A fan that stops, starts or runs on its own
  6. Compressor starts that the makers soften on purpose
  7. Defrost and changeover on heat pump PTACs
  8. Is crackling from the heat strip normal?
  9. Why is my PTAC rattling or humming?
  10. Dirty filters and blocked grilles make the unit work harder
  11. When to stop and call for service
  12. How loud should a PTAC be?
  13. Related guides and explainers
  14. What makers publish
  15. FAQs
  16. How we reviewed this article

Most of what you hear from a hotel or apartment PTAC is the unit doing what its makers designed it to do. The pinging, trickling and splashing come from condensate being thrown at the outdoor coil, and the clicks come from relays and the thermostat. The pauses and restarts are timers that protect the compressor.

Friedrich, GREE and Hotpoint print one line in their troubleshooting tables that covers most of it: clicking, gurgling and whooshing during operation are normal. The faults are a shorter list: rattles from loose parts or something in the airflow, a compressor that cycles on and off rapidly because air cannot get in or out, and a burned smell or a reset button that keeps tripping.

Each cause and fix below comes from owner's, installation and service manuals published by GE Appliances (Zoneline and Hotpoint), Amana, Friedrich and GREE, quoted with the model they cover. We did not run, measure or open any PTAC for this page. Window and through-the-wall air conditioners are different machines, covered on our page about window AC noises.

Why is my PTAC making noise?

A PTAC making noise is usually moving condensate, switching relays, starting its compressor or cycling its fan, which the makers call normal; rattles, rapid cycling and burned smells are the exceptions. Check in this order:

  1. Listen for pinging or trickling on a humid or rainy day, since GE, Hotpoint and Amana list that water sound as normal.
  2. Look at the fan setting, because a fan set to cycle stops and starts with the compressor on GE, Amana, Friedrich and GREE units.
  3. Wait about 3 minutes after a restart, which is the compressor delay GE, Friedrich and GREE print.
  4. Clean the intake filters, which Amana asks for once a month.
  5. Clear at least eight inches in front of the unit and check the outdoor grille for anything blocking it.
  6. Check that the wall sleeve still tilts slightly to the outside and that its caulking is sealed.
  7. Disconnect power and call the dealer for a burned smell, as GREE instructs.

For a PTAC that works properly but is too loud for a bedroom, the figures makers publish are on our quietest PTAC units guide.

Which PTAC sounds do the makers call normal?

Five sounds appear on the makers' normal lists: water pinging or trickling, clicks, a fan stopping and starting, gurgling and whooshing, and a pause of a few minutes before the compressor starts.

SoundCause the makers giveManuals that call it normal
Pinging, tricklingCondensate picked up from the base pan and thrown on the outdoor coilGE Zoneline, Hotpoint, Amana
ClickingRelays or the thermostat as the controls or compressor cycleGE Zoneline, Hotpoint, Friedrich, GREE
Gurgling, whooshingNot explainedFriedrich, GREE, Hotpoint
Fan stopping and startingFan set to cycle with the compressor or heaterGE Zoneline, Amana, Friedrich
Silence, then a startA built-in compressor delay of about 3 minutesGE Zoneline, Amana, Friedrich, GREE

The Friedrich ZoneAire Premier service manual gives its row for "Unit Making Noises" a single line: "Clicking, gurgling and whooshing noises are normal during operation of unit." The GREE PTAC II R32 owner's manual prints the same sentence. Neither manual says which part makes the gurgle or the whoosh.

Why does my PTAC sound like water splashing or pinging?

A PTAC pings and trickles because its outdoor fan scoops condensate out of the base pan and flings it on the condenser coil. GE, Hotpoint and Amana list the sound as normal, and say it helps efficiency.

GE's Zoneline AZE and AZH manual starts its normal sounds list with "You may hear a pinging noise caused by water being picked up and thrown against the condenser", which it ties to rain and high humidity. Hotpoint's AHES and AHHS manual carries the same entry, with the explanation that the feature "helps remove moisture and improve efficiency."

To Amana it is a trickle. Under "Water trickling sounds", its J and K series manual says "Water is picked up and distributed over the coil. This improves the efficiency and helps with water removal." Friedrich names the part in its ZoneAire Select manual: the condenser fan "utilizes slinger ring technology to pick up condensate from the base pan".

Leave the base pan water alone

On a Zoneline the water is meant to be there. GE's instruction to AZE owners is to leave the rubber drain plug in the base pan, because during cooling the water in the pan "promotes evaporative cooling and increases energy efficiency."

Water that overflows outside is expected too. Friedrich and GREE both call condensation runoff in very hot, humid weather normal when no drain kit has been installed. With a drain kit, they want its gaskets and fittings checked for leaks and plugs. Water inside is not. Both makers trace it to a wall sleeve that is not level.

Why is my PTAC unit clicking?

A PTAC clicks when its relays or thermostat switch the compressor, fan or heater on and off. On a Zoneline, relays click "when the controls cycle on and off or are adjusted to change the room temperature."

Hotpoint's manual pins the click on the thermostat as the compressor cycles. Both are normal. Neither signals a fault. A click when you press a button and nothing else happens is often the compressor delay, which is also by design. GE describes "a 3-minute delay" from a built-in restart protector if you restart the unit too soon or change the setting right after the compressor stops.

Friedrich and GREE use the same delay, and add a second one after a power cut. On the ZoneAire Select, the random restart staggers compressors across a building and "will range from 120 to 240 seconds." GREE's range is 2'45" to 3'15", and it pairs a 3 minute start delay with a 3 minute minimum run time so the compressor cannot short cycle.

Clicking on and off every few minutes

A compressor that clicks on and off rapidly can mean the unit is breathing its own air. Amana's wording is blunt: "If air is obstructed and/or deflected back into the unit, the air conditioner compressor may cycle on and off rapidly. This could damage the compressor or possibly void the warranty." The cure is airflow.

The outdoor side matters as much on a Zoneline. A rear grille that restricts or recirculates air "can cause the unit to cycle off due to the compressor overload protector", and GE adds that grilles from other makers "may be too restrictive for proper performance." Amana's J and K series manual calls for one of three Amana grille kits, and says an improper grille can shorten compressor life.

A fan that stops, starts or runs on its own

A PTAC fan that stops when the compressor stops is following its fan setting. Nothing is broken. Every maker here lets the owner choose between a fan that runs all the time and one that runs only while the unit is cooling or heating.

Amana's manual files this under "Air sounds". With the fan cycle switch ON, the fan runs whenever power is applied; on AUTO it "will cycle on and off with the compressor or electric heater." Friedrich's ZoneAire Select can be set separately for heating and cooling, and its troubleshooting table answers a fan that stops during operation with "It is normal when the CONSTANT FAN is OFF."

On a Zoneline the setting is called Smart Fan. Its defaults are a continuous fan in cooling and a cycling fan in heating, and in cycling cooling mode "the indoor fan will activate occasionally to verify air temperature in the room." GE's list of normal sounds adds that the fan may run longer than a cycle or kick on now and then "to improve room comfort and balance." A unit with a makeup air system keeps some fans running all the time.

Compressor starts that the makers soften on purpose

Several makers stagger the fan and the compressor so a start is less abrupt. GREE's method is simple. Its outdoor fan runs at minimum speed for 10 seconds before the compressor starts, to cut the compressor's starting noise.

Friedrich's version is named Quiet Start/Stop. The fan delays "prevent abrupt changes in room acoustics due to the compressor energizing or stopping immediately", and the fan keeps running for 60 seconds after the compressor stops to use the cold coil. On ZoneAire Select units Friedrich also credits a dual-motor design, saying the indoor motor "can run at slower speeds which reduces sound levels indoors."

None of these manuals describes a hum, a thud or a buzz at compressor start, and none gives a sound that marks a failing compressor. Friedrich's service manual leaves abnormal compressor sound to the technician's checklist.

Defrost and changeover on heat pump PTACs

A heat pump PTAC that goes quiet in cold weather may be defrosting. During GE's defrost cycle, "both the indoor and outdoor fans stop and the compressor operates in the cooling mode to remove frost from the outdoor coil." It is on GE's list of normal sounds.

On the Zoneline AZE and AZH, the unit then restarts in electric heat to warm the room quickly. Cold weather changes the sound in another way too, because the heat pump hands over to the electric strip. GREE switches to electric heating at about 28°F outdoors and goes back to the compressor at about 40°F. Amana switches a PTH unit to strip heat "when the coil temperature is below 20°F", or when the heat pump cannot keep up and a two stage thermostat is used.

Two outdoor coil frost lockouts in Amana's fault table, LE and LF, carry the note "Can be normal operation in low outside ambient." The reversing valve that swaps heating and cooling appears only in Friedrich's service manual, as a job for a technician, and no owner's manual here ties a sound to it.

Is crackling from the heat strip normal?

No maker in this group lists crackling, ticking or popping from the electric heater, in either the normal sounds or the troubleshooting tables.

Without a maker statement there is no fix to quote. A crackle that keeps coming back is a question for the servicer.

What the manuals do cover is smell. On a Zoneline, dust on the heating elements "can cause a 'burning' odor at the beginning of the heating operation", and that it "should quickly fade." The ZoneAire Select table expects the bad smell from dust on the E-heater to "disappear a little later."

The heater's safety limit shows up only as a code. In Friedrich's ZoneAire Premier service manual it is C7, an electric heater "limiter switch open too long", with a damaged element or loose wiring as causes. Amana's L6, "Electric discharge too hot", has the owner clean the filter or remove the air blockage.

Why is my PTAC rattling or humming?

A rattling PTAC usually has a loose part or something caught in the airflow. Friedrich's ZoneAire Select table blames noise on moving parts that "get loose fixing or cause bad vibration", or "Something in the air way."

The fix in that row is to make sure all moving parts are assembled well and nothing sits in the airflow. Friedrich's service manual also warns that the unit "should not be in contact with any equipment that will transmit vibration to the unit", because vibration or pulsation can damage the refrigerant tubing.

The sleeve is the other place to look. Amana's maintenance section includes checking the caulking around the sleeve and rechecking its level, which for most installations means "a ¼ bubble tilt to the outside and level from right to left." Friedrich and GREE both make a level sleeve the cure for water dripping inside. For the sleeve and grille choices behind a quiet installation, see the quietest PTAC units guide.

Humming has no entry in any manual used here, as normal or as a fault, so a hum that changes with the compressor or fan belongs with a servicer rather than a guess.

Dirty filters and blocked grilles make the unit work harder

A clogged filter or blocked grille starves the coil of air, which the makers link to frost, overheating and rapid cycling. Amana asks for the intake filters to be cleaned once a month, more often in dusty locations.

Amana also wants a minimum of eight inches between the unit and furniture or beds, and warns that severe airflow restrictions can damage the compressor, electric heater or fan motor. Its fault codes point the same way: LC, an outdoor coil hot lockout, asks for clean condenser coils and a check of the fan.

The indoor coil can freeze. Friedrich and GREE say frost may form on it in cooling when it is about 55°F or below outside, or when filters are dirty. Switch the unit to FAN until the ice melts. On ZoneAire Select units a frost sensor stops the compressor at 33°F on the indoor coil and lets it restart at 59°F, with the fan still running.

GE's Zoneline manual asks for the outdoor coils to be checked regularly and cleaned by low or no pressure methods if dirt or soot clogs them. The unit has to come out of the sleeve for that.

When to stop and call for service

Stop using a PTAC that gives off a burned smell or keeps tripping its power cord or breaker. GREE's instruction for an abnormal condition such as a burned smell is short: "please disconnect power at once and then contact local dealer."

GE's rule for its power cord current interrupter is similar. If the RESET button will not stay engaged, GE says to discontinue use of the Zoneline and contact a qualified service technician. GREE adds that a breaker that trips, or a fuse that blows, more than once is a job for a qualified electrician.

Past those, the inside of the unit is not owner territory. Leave it to the servicer. Repairs beyond the Amana manual go to an authorized service organization, and GREE's own manual reserves repairs for specialists. The LED fault codes in the Amana, Friedrich and GREE manuals give the servicer a starting point.

How loud should a PTAC be?

A PTAC running normally is rated at 46 to 50 dB(A) indoors on the quietest 9,000 BTU models. Friedrich and GREE both print 46 dB(A) sound pressure on low and 50 on high, the figures on our quietest PTAC units guide.

Across a whole range the numbers climb. The ZoneAire PTAC figures on our Friedrich air conditioner decibels chart span 45 to 63 dB(A) indoors. Zoneline is the odd one out, sold by GE as the quietest PTAC with no operating figure printed for it. None of the makers publishes a decibel level that signals a fault, so judge a noisy unit by the sound it makes and the conditions around it, as set out above.

For a replacement, compare the quietest PTAC units and the quietest through-the-wall air conditioners, which fit a smaller sleeve. Heat pumps that sit in a window are on our quietest window heat pumps guide.

Sounds from related machines have their own pages: window AC noises, mini-split noises and heat pump noise. To quiet a window unit that works properly, read how to make a window AC quieter.

What makers publish

The noise figures makers print for models in our buying guides, word for word, with any setting or distance they give. Figures taken under different conditions are not comparable, so this list does not rank them.

The quietest PTAC units

ModelNoise figure, as published
Friedrich ZoneAire Premier R-32 9,000 BTU PTAC Heat Pump with Electric Heat, 230/208V50 / 46 dB(A) sound pressure, high / low
GREE PTAC II R32 9,000 BTU Heat Pump with Backup Electric Heat, 230/208V50/46 dB(A) sound pressure, speeds not named
ACiQ 9,000 BTU Inverter PTAC Heat Pump with 3.5kW Electric Heater, R3249/48/47 dB(A) sound pressure, speeds not named
Friedrich ZoneAire Premier R-32 9,000 BTU PTAC with Electric Heat, 230/208V50 / 46 dB(A) sound pressure, high / low
ACiQ 12,000 BTU Inverter PTAC Heat Pump with 3.5kW Electric Heater, R3251/50/49 dB(A) sound pressure, speeds not named

All 6 models in the guide

The quietest through-the-wall air conditioners

ModelNoise figure, as published
Frigidaire 10,000 BTU Wall Room Air Conditioner50.2 / 52.8 / 56 dBA, low to high (maker)
LG 8,000 BTU Through-the-Wall Air Conditioner56 / 55 / 53 dBA high to low; 56 indoor, 62 outdoor (maker)
Frigidaire 8,000 BTU Wall Room Air Conditioner with Supplemental Heat52 / 54 / 57 dBA, low to high (maker)
Keystone 8,000 BTU 115V Through-the-Wall Air Conditioner with Follow Me LCD Remote Control56.8 / 51.8 dBA indoor, speeds not named on the sheet (maker)
Frigidaire 12,000 BTU Wall Room Air Conditioner55.3 / 56.8 / 59 dBA, low to high (maker)

The quietest window heat pumps, and how cold each one keeps heating

ModelNoise figure, as published
Gradient All-Weather 120V Window Heat Pump47 / 44 / 38 dB(A), high / medium / low, mode not stated (maker)
GE ENERGY STAR 8,000 BTU Smart Heat/Cool with Heat Pump Electronic Window Air Conditioner for Medium Rooms up to 350 sq. ft.40/59 dBA (Quiet Mode, Low Cool) (maker)
SoleusAir 12,000 BTU Saddle Air Conditioner with WiFi38 to 48 dB(A) indoor, 3.28 ft, cooling mode (maker)
Midea 8,000 BTU DOE Smart Heat/Cool Inverter Window Air Conditioner, for spaces up to 350 sq. ft.As low as 45 dBA, no speed or mode named (maker)
GE ENERGY STAR 11,000 BTU Smart Heat/Cool with Heat Pump Electronic Window Air Conditioner for Large Rooms up to 550 sq. ft.40/61 dBA (Quiet Mode, Low Cool) (maker)

The quietest window air conditioners for a bedroom

ModelNoise figure, as published
Frigidaire Gallery 8,000 BTU Inverter Window Room Air Conditioner with Wi-Fi (Energy Star)40 / 46 / 50 dBA, low to high (maker)
Midea 8,000 BTU DOE U-Shaped Smart Window Air Conditioner, for spaces up to 350 sq. ft.As low as 32 dBA (maker, speed not stated)
LG 8,000 BTU Dual Inverter Smart Wi-Fi Enabled Window Air Conditioner | Cools Up To 350 sq. ft.54 / 50 / 46 / 44 dBA, high to sleep (maker)
The Windmill AC - 8K BTU WhisperTechStarts at 42 dB (maker, one figure)

Frequently asked questions

Is it normal for a PTAC to make a dripping or splashing noise?

Yes. GE, Hotpoint and Amana list it as normal: the outdoor fan picks up condensate from the base pan and spreads it over the coil. Friedrich and GREE also call outdoor dripping in hot, humid weather normal when no drain kit is fitted.

Why does my PTAC click but not turn on?

Usually a built-in delay. GE, Friedrich and GREE hold the compressor off for about 3 minutes after a restart, and Friedrich adds 120 to 240 seconds after an outage. If a Zoneline cord RESET button will not stay in, GE says stop using it.

Why does my PTAC fan keep turning on and off?

Most often because the fan is set to cycle with the compressor or heater. GE's Smart Fan setting, Amana's fan cycle switch and the constant fan option on Friedrich and GREE units decide whether the fan runs all the time.

Why did my heat pump PTAC go quiet in winter?

It may be defrosting. GE says both fans stop during its defrost cycle while the compressor runs in cooling mode to clear frost off the outdoor coil. GREE and Amana also switch heat pump models to strip heat in cold weather.

Should a PTAC smell like burning?

GE and Friedrich attribute a brief burning smell at the start of heating to dust on the heating element, which should fade. GREE says to disconnect power at once and contact the dealer for an abnormal condition such as a burned smell.

How we reviewed this article

Every statement here comes from the 6 maker documents, standards and agency pages listed under Sources, quoted where the wording matters. We did not measure, inspect or repair anything ourselves. Each substantive revision is dated below. How we work

  1. Current version

    PTAC noise page goes live, quoting owner's manuals, installation manuals and service manuals from GE Appliances (Zoneline and Hotpoint), Amana, Friedrich and GREE.

  2. First published, written by Stanley Alu.

Sources

Written by

Stanley Alu

Founder and editor

I founded QuietSpecs after running a product review blog, and I built it around the spec that is hardest to pin down. With noise, makers tend to quote the quietest setting they can find, or nothing at all. So I read the spec sheets, manuals and certification directories, quote each figure with the setting it describes, and say so plainly when a maker publishes none. I do not test products or measure decibels, and no brand pays for a place in a guide.