QuietSpecs

RV fridge making noise? Clicking on gas, gurgling and beeps explained

Written by · Checked against 8 sources
· 12 min read

The clicking when an RV fridge lights on propane is its spark igniter, tried for about 45 seconds by Dometic and 30 by Norcold. What the makers say about beeps, gurgling, ammonia and level.

Key takeaways

  • On propane, the clicking from a gas and electric RV fridge is its igniter sparking. Norcold allows a 30 second trial for ignition, Dometic about 45 seconds, and no maker document calls the sound clicking.
  • Norcold and Dometic both name air in the propane line when the burner will not light, which Norcold expects after storage or a tank change. Norcold allows two or three tries before you stop and consult a dealer.
  • Gurgling means opposite things on the two types. Furrion calls it normal refrigerant flow on its 12V compressor fridges, while Norcold's Polar service manual counts it among the signs of an absorption cooling unit leak.
  • An ammonia smell is a stop sign. Dometic's manual tells owners to switch the fridge off at the control panel, air out the RV and evacuate.
On this page
  1. Why is my RV fridge making noise?
  2. Why does my RV fridge click on gas?
  3. Clicking that keeps going with no flame
  4. Why is my RV fridge beeping?
  5. Is gurgling normal in an RV fridge?
  6. An ammonia smell means switch it off
  7. Hums, rattles and vibration on 12V compressor models
  8. Level matters more on a gas and electric fridge
  9. Blower noise on Norcold Polar fridges
  10. When to stop and call a dealer
  11. Related guides and explainers
  12. What makers publish
  13. FAQs
  14. How we reviewed this article

Two very different machines get sold as an RV refrigerator, and they make different sounds. A gas and electric unit, the absorption type in Dometic's DM and DMA range or Norcold's N61X, N81X and Polar models, cools with heat instead of a compressor. That heat comes from a propane burner or a 120 VAC heater, which the Polar service manual lists among the parts at the back. Its noises come from lighting the flame, from alarms when lighting fails, and sometimes from a fan.

A 12V compressor fridge, such as the Dometic DMC4081 and DMC4101, the Norcold N8DCX and N10DCX or Lippert's Furrion Arctic and Everchill units, cools with a compressor, like a kitchen fridge. Its manuals tie extra noise to level, wall contact and vibration rather than to gas.

What follows comes from owner's, operating and service manuals published by Dometic, Norcold (now part of Thetford) and Lippert, which sells the Furrion and Everchill brands. Nothing here was run or measured by us. The three makers also leave decibel ratings off their built-in RV fridges, so this page has none to give.

Why is my RV fridge making noise?

An RV fridge making noise is usually doing one of a few things, and which ones depend on its type: lighting a gas burner and sounding an alarm on an absorption model, or starting a compressor and fan on a 12V model.

SoundFridge typeWhat the manuals tie it to
Ticking or clicking on propaneGas and electric (absorption)Electronic igniter during the trial for ignition (Norcold, Dometic)
Ticking that repeats, no flameGas and electricAir in the propane line (Norcold, Dometic)
BeepingGas and electricFailed ignition or no power source (Dometic CHECK lamp, Norcold fault codes)
Fan or blower whirNorcold Polar with freezer blowerOptional blower, which the owner can switch off
GurglingGas and electricListed as a possible leak sign (Norcold Polar service manual)
Bubbling or gurgling12V compressorNormal refrigerant flow (Furrion Arctic)
Popping or cracking at compressor start12V compressorMetal expanding and contracting, normal (Furrion Arctic)
Rattle, vibration, unusual noise12V compressorNot level, or touching a wall (Dometic DMC, Everchill, Furrion)
Hum or buzz on 120 VACGas and electricNot explained by any of the three makers

A GAS setting on the control panel is the quickest way to tell the types apart. The absorption models in these manuals have one. The Dometic DMC, Norcold N8DCX and N10DCX, and Furrion units have no gas mode at all.

Why does my RV fridge click on gas?

The clicking on gas is the spark igniter trying to light the propane burner. Norcold's N61X and N81X manual describes it this way: "During the 30 second trial for ignition, the refrigerator controls open the gas safety valve and the igniter sparks."

No maker document we found calls that sound clicking. Dometic's operating manual, Norcold's owner's manuals and the Polar service manual all describe sparks and ignition attempts, and leave the sound itself unnamed. A spark igniter fires as a quick run of ticks, and that run of sparks is what gets searched for as clicking on gas. The one click Norcold's owner's manuals do mention belongs to the travel door latch, which should click as each door is pushed shut.

Dometic's timing is longer. In gas mode on the DM2672, DMA4061, DM2872 and DMA4081, "The control system activates the ignition system and attempts to light the burner for about 45 seconds." The Polar 7 and Polar 8 service manual names the part: "The controls use an electronic sparker to ignite the propane gas at the burner."

Norcold also explains the limit. On Polar models the trial for ignition, which it defines as the "maximum amount of the time the gas valve and igniter can be left on without a flame present", is capped at 30 seconds for safety.

Clicking that keeps going with no flame

Repeated sparking with no flame points to air in the propane line, according to both Norcold and Dometic. Norcold's Polar manual says the lines can hold air at a first start, after storage or after a tank change, and both makers clear it by running more ignition cycles.

The N61X and N81X owner's manual walks through it. If air stops the burner from lighting, after 30 seconds the controls close the gas valve "and the igniter stops sparking", and the ON and GAS lights flash about once a second. Push the selector to OFF, then back to GAS, and a new 30 second trial begins.

It may take more than one go. Norcold allows that "you may need to repeat the 30 second trial for ignition two or three times," and then draws a line: "If the burner does not ignite on propane gas after two or three attempts, stop and consult your local dealer or an authorized Norcold Service Center."

Dometic's troubleshooting table for a fridge that will not run in gas mode is shorter. Check the LP tank and change it if needed, then "Purge air from the gas line by repeating the ignition sequence." If the problem persists, Dometic wants the fridge turned off and a Dometic dealer or service center called. Neither maker prints any further owner fix for the igniter.

Why is my RV fridge beeping?

An RV fridge beeps when it has no working energy source, for example after the burner fails to light. On Dometic DM and DMA models the beep comes with a flashing CHECK lamp, and both keep going until you restart the fridge.

The DM and DMA operating manual puts it in two lines: "If the burner fails to ignite, the CHECK indicator lamp will flash on and off, and a buzzer will beep." Then: "The CHECK indicator lamp and buzzer will not turn off until the refrigerator is restarted, even if AC becomes available." Plugging into shore power does not silence it.

Norcold uses fault codes on its Polar line. On 2-way models with neither 120 volts AC nor propane available, the Polar N7 and N8 owner's manual says the fault codes no AC and then no FL show in the display and "an audible alarm sounds." On N7LX and N8LX models a flashing "no" "FL" with an alarm means the burner did not ignite or re-ignite. Norcold's reset is to turn the fridge off and back on, then check that the tank valve and the fridge's manual gas valve are open, the gas pressure is right and the supply line holds no air. Past that, the fault code table sends you to the dealer.

Is gurgling normal in an RV fridge?

Gurgling is normal on a 12V compressor RV fridge, according to Furrion. On a gas and electric absorption fridge, Norcold treats it as one possible sign of a leaking cooling unit, so the two types need separate answers.

The Furrion Arctic instruction manual lists "Bubbling or gurgling sounds (like boiling water)" with the explanation "This is the normal sound of refrigerant (used to cool refrigerator) circulating throughout the system." That matches what makers of home compact fridges say, covered in our mini fridge gurgling section.

Norcold reads the same sound very differently on an absorption unit. There, it can mean a leak. In the Polar service manual's diagnosis chart, "Visual and audible signs of leak(s):" lists "Yellow residue on the rear of the refrigerator.", "Ammonia smell." and "Gurgling noise (not always present)." When a sign is present, the technician's next step in that chart is "Replace cooling unit."

Dometic's DM and DMA manual says nothing about gurgling either way, which leaves owners of a Dometic absorption fridge without a maker statement. Norcold marks the gurgle as not always present. The other two signs on its list are ones an owner can check: yellow residue on the back of the fridge, and the smell.

An ammonia smell means switch it off

Dometic treats an ammonia smell from an absorption RV fridge as an emergency: turn the fridge off immediately at the front control panel, open the RV up and get out.

The full remedy in Dometic's DM and DMA troubleshooting table reads, in order: "Immediately turn the refrigerator off at the front control panel." "Do not open refrigerator doors." "Open RV windows and doors (to air out the RV) and evacuate." After that, turn off the manual LP gas valve at the rear of the fridge, disconnect the 120 VAC power at the rear, contact a Dometic dealer or service center, and do not use the fridge until it has been repaired.

Its safety section adds that if the fridge stops working or "emits an ammonia smell, immediately turn refrigerator off (if it is safe to do so), leave the vicinity, and contact a qualified Service Center." Norcold lists the ammonia smell among its leak signs, as quoted above. We add nothing to these steps.

Hums, rattles and vibration on 12V compressor models

Unusual noise from a 12V compressor RV fridge traces to two causes in the makers' tables: the fridge is not level, or its body touches a wall.

Dometic's DMC4081 and DMC4101 manual answers "The refrigerator seems to make unusual noise." with exactly those causes: "The refrigerator is not leveled on the floor." and "The body of the refrigerator touches a wall." The fix for the second is to ensure "proper clearances around the refrigerator." The same manual offers a Silent Mode in which "The compressor works at a constant speed while the outer fan works at low speed," limited to temperature level three and below.

The Everchill troubleshooting and service manual uses two questions under "Abnormal noise": "Is refrigerator stable?" and "Does refrigerator contact the wall?" Its answers are to adjust the leveling feet and to "Keep proper space between the refrigerator and walls."

Lippert's Arctic manual is more relaxed about some sounds. It calls "Popping or cracking sounds when compressor comes on" normal, comparing them to hot water pipes, and says "slight vibration is normal". Rattling has two listed causes, an uneven or weak surface and the temperature setting, where "max position, may affect the vibration level." The same manual frames the Arctic for 0" clearance at the sides and top, with an intentional 1/4" gap behind it for the service wire.

None of the three makers explains a hum or a buzz from an absorption fridge running on 120 VAC. We found no statement calling it normal or a fault, so we cannot point to a cause.

Level matters more on a gas and electric fridge

An absorption RV fridge has a much tighter level limit than a compressor model. Norcold gives 3° side to side and 6° front to back for its N61X, N81X and Polar fridges, against 10° in all directions for the N8DCX and N10DCX.

Off level, the absorption models risk more than noise. The risk is damage. Norcold's caution for the N61X and N81X says operating beyond those limits "can cause damage to the cooling system and create a risk of personal injury or property damage." Dometic's DM and DMA rule is that the fridge "must be kept level when the RV is parked for several hours or more," because cooling can be lost if it runs noticeably out of level for hours. Travel is a different case: "It is not critical for the refrigerator to be level when traveling."

The compressor models are looser but still name noise. Norcold's N8DCX and N10DCX manual warns that going past its 10° limit "can cause damage to the cooling system, increased noise and poor cooling performance." Furrion accepts "A slope that is comfortable to live with" for the Arctic.

Blower noise on Norcold Polar fridges

Some Polar 7 and Polar 8 fridges carry an optional freezer blower, and Norcold says owners can turn it off. The trade, in the service manual's words, is that switching it OFF "will eliminate the blower noise and also reduce the ice production."

The switch ships in the ON position, which Norcold says gives the most ice. The Polar owner's manual adds that for maximum ice production the freezer blower must be on, so the quieter setting means less ice.

When to stop and call a dealer

Stop and call a dealer when the burner still will not light after two or three trials, when the fridge stops cooling, or when you smell ammonia. Those are the points at which Norcold and Dometic hand the job to a service center.

For a DM or DMA fridge that stops cooling, Dometic is firm: turn it off immediately, contact a dealer, do not leave it running, and "Do not attempt to solve the problem by repeatedly restarting the refrigerator." A fridge that gives off an odor from fumes gets a similar instruction: turn it off and contact a Dometic dealer or service center. Norcold's Polar manual likewise ends repeated failed ignitions with "stop and consult your local dealer or Authorized Norcold Service Center."

The owner steps printed for 12V compressor models are leveling, clearance and the mode or temperature setting. A noise that survives those has no further owner fix in the Dometic, Norcold or Lippert documents.

QuietSpecs has no buying guide for built-in RV fridges, because the makers we checked publish no noise figure for them. For portable 12V fridges and coolers, where Dometic and Whynter do print figures, see the quietest 12V fridges guide and its section on absorption, thermoelectric and compressor coolers. Compact fridges for a cabin or office are on the quietest mini fridges page.

The rest of a camper has its own noise sources. Roof units are ranked on our quietest RV air conditioners guide, with tips in how to make an RV air conditioner quieter. Generators are covered by the quietest RV generators guide and generator noises explained. Household fridge sounds are in refrigerator noises explained.

What makers publish

The noise figures makers print for models in our buying guides, word for word, with any setting or distance they give. Figures taken under different conditions are not comparable, so this list does not rank them.

Quietest 12V fridge: the Dometic CFX3 100 at 36.5 dB(A), and five more with real figures

ModelNoise figure, as published
Dometic CFX3 100 Powered Cooler, 99 L, 12/24 V DC and AC (9600024623)"Noise emission: 36.5 dB(A)" (Dometic AMER manual, no distance stated)
Dometic CFX3 35 Powered Cooler, 36 L, 12/24 V DC and AC (9600024617)"Noise emission: 44 dB(A)" (Dometic AMER manual, no distance stated)
Dometic CFX3 25 Powered Cooler, 25 L, 12/24 V DC and AC (9600028370)"Noise emission: 46 dB(A)" (Dometic AMER manual, no distance stated)

The quietest mini fridges, by the makers' own noise figures

ModelNoise figure, as published
Summit MB41B Compact Refrigerator, 1.6 cu ft32.9 dB (maker, lab-tested)
Summit CP34W Two-Door Compact Refrigerator-Freezer, 3.2 cu ft33.2 dB (maker)
Danby 2.2 cu ft Compact All-Refrigerator40 dB (maker)
Midea 3.1 cu ft Double-Door Compact Refrigerator42 dBA (maker)

The quietest RV air conditioners, by the figures makers publish

ModelNoise figure, as published
TOSOT 16,000 BTU RV Air Conditioner with Heat Pump56 / 52 / 43 dB, high to low (maker)
Nomadic Cooling X2 Compact 48V/24V/12V Off-Grid DC Rooftop Air Conditioner≤ 60 dBa (maker, one figure)
TURBRO Greenland 13,500 BTU Inverter Rooftop RV Air Conditioner with Heat Pump45 dB minimum (maker, one figure)

Quietest RV generator: built-in Onan sets at 10 ft and RV-ready portables

ModelNoise figure, as published
Cummins Onan QG 2800i Built-In RV Generator (Gasoline EFI)65 dBA at 10 ft (3 m), half load (Cummins handbook)
Cummins Onan QG 4000i Built-In RV Generator (Gasoline EFI)66 dBA at 10 ft (3 m), half load (Cummins handbook)
Cummins Onan QD 8000 Quiet Diesel Built-In RV Generator66 dBA at 10 ft (3 m), half load (Cummins handbook)
Cummins Onan QG 5500 EFI Built-In RV Generator (Gasoline)69 dBA at 10 ft (3 m), half load (Cummins handbook)
Cummins Onan QG 7000i DF Dual Fuel Built-In RV Generator69 dBA at 10 ft (3 m), half load (Cummins handbook)

All 13 models in the guide

Frequently asked questions

Do RV fridges make noise?

Both kinds do, in different ways. A gas and electric absorption fridge ticks while its igniter lights the propane burner and beeps when ignition fails. A 12V compressor fridge starts and stops a compressor, and Furrion lists bubbling, popping and slight vibration as normal on its Arctic models.

Why does my Dometic RV fridge click on gas?

Its ignition system is trying to light the burner. Dometic's DM and DMA manual says the controls attempt this for about 45 seconds in gas mode. If the burner never lights, the CHECK lamp flashes and a buzzer sounds until the fridge is restarted.

Why does my RV fridge keep clicking but not lighting?

Both Norcold and Dometic name air in the propane line, which Norcold expects after storage or a new tank and Dometic clears by repeating the ignition sequence. Norcold has you switch to OFF and back to GAS to start another trial, two or three times, then stop and consult a dealer if no flame appears.

Is gurgling normal in a camper fridge?

It depends on the cooling system. On Furrion's 12V compressor fridges, bubbling or gurgling is listed as the normal sound of refrigerant. On a Norcold Polar gas and electric fridge, the service manual puts a gurgling noise beside yellow residue and an ammonia smell as signs of a cooling unit leak.

Why is my RV fridge making noise but not cooling?

Treat it as a fault. For a DM or DMA fridge that stops cooling, Dometic says to turn it off at once, contact a dealer and not keep restarting it. On a 12V compressor model, check that it is level and not touching a wall, the two noise causes Dometic and Lippert print.

How we reviewed this article

Every statement here comes from the 8 maker documents, standards and agency pages listed under Sources, quoted where the wording matters. We did not measure, inspect or repair anything ourselves. Each substantive revision is dated below. How we work

  1. Current version

    First published, from owner's, operating and service manuals by Dometic, Norcold (Thetford) and Lippert (Furrion and Everchill).

  2. First published, written by Stanley Alu.

Sources

All 8 sources

Written by

Stanley Alu

Founder and editor

I founded QuietSpecs after running a product review blog, and I built it around the spec that is hardest to pin down. With noise, makers tend to quote the quietest setting they can find, or nothing at all. So I read the spec sheets, manuals and certification directories, quote each figure with the setting it describes, and say so plainly when a maker publishes none. I do not test products or measure decibels, and no brand pays for a place in a guide.

How we compare products

Related buying guides

More in Why Is It Noisy