Generator making noise? What surging, popping, knocking and hissing point to

Written by · Checked against 13 sources
· 13 min read

Surging, which maker tables call hunting, points first to stale fuel, a dirty carburetor or a blocked filter. Popping, knocking, hissing at the starter and rattles each get their own causes in Honda, Champion, Generac, Predator and WEN manuals.

Key takeaways

  • Champion, WEN and Firman all print a row for surging, which their tables call hunting, and all three blame a dirty carburetor or a restricted fuel valve or filter among the causes.
  • Some change in speed is designed in: Generac's iQ3500 manual calls engine speed that rises and falls "normal as generator starts up and loads vary".
  • Harbor Freight's Predator 3500 table links backfiring to poor gasoline, a cold engine, a stuck intake valve or wrong timing, and a hiss at the starter to a loose spark plug or head gasket.
  • A Generac home standby unit that starts by itself is exercising for about five minutes, and with Quiet-Test on its speed drops after roughly 40 seconds.
On this page
  1. Speed that follows the load is normal
  2. Why is my generator surging?
  3. Old fuel shows up in many of these rows
  4. Why does my generator make a popping noise when running?
  5. Why is my generator knocking?
  6. A hiss when you pull the starter
  7. Rattles, shaking and loose parts
  8. Why does my standby generator run by itself?
  9. When to stop and call for service
  10. How loud is a generator that is running properly?
  11. Quieter running, placement and buying
  12. What makers publish
  13. FAQs
  14. How we reviewed this article

Of all the sounds a generator can make, surging gets the most rows in the makers' troubleshooting tables. Owners hear it as a rhythmic chugging, the engine speeding up and slowing down while nothing has changed, and the troubleshooting tables in Champion, WEN and Firman manuals trace it to fuel, a dirty carburetor or a clogged filter.

Some speed change is designed in. An eco or idle switch drops the engine to a slower pace when the load is light and brings it back when something is plugged in, and a home standby unit slows itself down for its weekly exercise run. The sections below separate those expected sounds from the ones the makers treat as faults: popping, knocking, hissing at the starter, rattles and heavy vibration.

Each cause and fix comes from the troubleshooting tables, manuals and help pages of Honda, Champion, Generac, Harbor Freight (Predator), WEN, Westinghouse, Firman, DuroMax and Briggs & Stratton, quoted with the model it applies to. None of them uses the words chugging or revving. Those sounds are matched here to the symptom names the tables do use, such as hunting, faltering and running rough.

Speed that follows the load is normal

An engine note that rises when you plug something in and falls when you unplug it is the generator working as designed. Generac's iQ3500 manual closes its troubleshooting table with a footnote on "Engine speed increases and decreases", and its verdict is "This is normal as generator starts up and loads vary."

Idle and eco switches make the swing bigger. The idle control on DuroMax's XP13000EH "lowers the RPM of the generator when there is no load to save gas and decrease engine noise", and "When a load is applied, the engine will resume normal speed to provide usable power." Which loads need the switch off differs from brand to brand, and that list is on our page about how to make a generator quieter.

A new engine can vary on purpose too. Champion's 100592V manual, for its 6250W dual fuel model, treats the first 5 hours as break-in. Owners are asked to stay at or below half the running watt rating and change the load now and then, because "Adjusting the load will also cause engine speed to vary slightly and help seat piston rings."

Why is my generator surging?

A generator surges, or hunts, when fuel or air reaches the engine unevenly. The four maker pages that name the symptom put a dirty carburetor, a restricted fuel valve or filter, and a blocked air or exhaust path near the top.

Manual or pageSymptom as printedCauses listed
Champion 201530 2500W dual fuel inverter"Generator hunts or falters.""Engine governor defective.", "Dirty fuel valve.", "Carburetor is dirty and running lean.", "Choke lever in wrong position."
WEN 56450iX inverterEngine "Hunting" during operation, with the RPM fluctuatingFuel not flowing through the fuel valve, a clogged air filter, a blocked muffler or spark arrester, "gunk in the carburetor preventing a consistent fuel/air mixture"
Firman P03504 portableEngine "hunts" or falters"Carburetor is running too rich or too lean.", "Clogged or dirty fuel filter."
Briggs & Stratton home standby page"surging or inconsistent power"The air filter, the spark plug, fuel pressure

Owners can handle part of it. The WEN 56450iX manual has you check that fuel moves "properly and consistently" through the valve, clean the air filter, scrub the spark arrester with a metal brush, and "Use 'gunk remover' spray on the carburetor jets." For a defective governor or a lean, dirty carburetor, the Champion 201530 manual gives one answer: "Contact the help line." Firman sends a carburetor running rich or lean to an authorized service facility, in its P03504 manual.

Standby units get a short checklist from Briggs & Stratton. Its rough running page names an air filter that is "restricted, old, or damaged", a spark plug that is damaged or wrongly gapped, and fuel. Checking fuel levels "can be a great first step", and the rest of the fuel system is left to the dealer or service provider.

Why does my generator surge at idle or with no load?

An unloaded engine that surges is often still cold or has the choke in the wrong place. DuroMax has owners turn the idle control off at start-up "to prevent the unit from trying to idle down before the engine is warmed up."

Generac lists "Unit not warmed up." among the causes of rough running on the iQ3500, along with a stuck choke, a gummed carburetor, a clogged spark arrestor and dirt in either the air or the fuel filter. For the cold engine its fix reads "Gradually adjust Dial and reduce choke until engine runs smoothly in RUN position." Champion's two manuals count a choke in the wrong position as a cause of hunting too.

Surging or bogging under load

Under load, the usual suspects are too many appliances and too little air. The Westinghouse iGen1500c manual has a row for "Engine runs rough or bogs when load applied" that lists a dirty air filter, "Generator overloaded.", a faulty tool or appliance, and "Fuel system malfunction, ignition malfunction, or valves stuck." The fix for overload is "Unplug some devices." The last cause goes to customer service.

Harbor Freight's Predator 3500 manual has a row for an engine that stops under heavy load. A dirty air filter is one cause, an engine running cold the other, and for that the advice is "Allow engine to warm up prior to operating equipment."

Surging after a new carburetor

Replacement carburetors are outside every manual on this page; none says what to do when a new one surges. What they do say narrows the options.

Champion's 100592V manual states "The air-fuel mixture is not adjustable" and warns that tampering with the governor "can damage your generator and your electrical devices and will void your warranty." Honda's EU2200i manual counts "Removal or alteration of any part of intake, fuel, or exhaust systems" as tampering and recommends Honda Genuine parts, while also allowing "comparable EPA certified parts". A surge that begins with a new carburetor belongs with the maker's help line or dealer.

Surging, then the engine dies

An engine that surges and then quits is usually running short of fuel or shutting itself down for protection. Generac's iQ3500 row for "Engine starts, then shuts down." lists running out of fuel, an incorrect oil level, contaminated fuel and a defective low oil level switch.

The Predator 3500 adds "Defective fuel tank cap creating vacuum, preventing proper fuel flow." Honda's EU2200i manual says the fuel cap vent lever "must be in the ON position for the engine to run", and Generac's iQ3500 warns of poor performance with its cap vent off. Low oil sensors can trip on uneven ground, and the Predator table has a line for it: "Engine mounted on slope, triggering low oil shutdown."

Carbon monoxide shutoffs are the other kind of stop. On the Champion 201530, exhaust blowing back into the operating area can trip the CO Shield, and the fix is to "turn the generator 45° in either direction to allow the exhaust emissions to blow away from the generator." For any CO shutoff the manual also says "Move generator to an open, outdoor area. Point exhaust away from people and buildings. Move to fresh air and get medical help if sick, dizzy, or weak."

Old fuel shows up in many of these rows

Stale gasoline shows up in the surging, misfiring, knocking and backfiring rows of these tables. Honda warns that "Fuel deterioration and oxidation can occur in as little as 30 days," and that old gasoline "leaves gum deposits that clog the fuel system."

Briggs & Stratton gives untreated gas "about a month" before it starts to break down, and its problem solving page calls stale fuel, dirt and debris "the most common cause of outdoor power equipment not starting or running properly." The remedies agree across makers. Drain the tank and the carburetor, refill with fresh gasoline, and treat any fuel that will sit. Harbor Freight asks for "fresh 87+ octane stabilizer-treated unleaded gasoline" in the Predator 3500, and nothing above 10% ethanol.

Why does my generator make a popping noise when running?

A pop while a generator runs is a backfire. The Predator 3500 table gives four causes: "Impure or low quality gasoline.", "Engine too cold.", "Intake valve stuck or overheated engine." and "Incorrect timing."

Fresh fuel is the answer to the first. For a cold engine the manual says "Use cold weather fuel and oil additives to prevent backfiring." A stuck valve or an overheated engine goes to a qualified technician.

Honda puts "Misfiring or backfiring under load." and "Afterburning (backfiring)." among the emissions-related symptoms its EU2200i manual hands to an authorized Honda Power Equipment dealer. Misfires have their own Predator row. The causes run from a loose or defective spark plug cap and a damaged or wrongly gapped plug to old gasoline and incorrect compression.

A pop after you shut it off

A bang once the engine has stopped is afterfire, in Briggs & Stratton's terms. Its backfire page blames "Shutting off the engine at high RPM, causing fuel to pump through the engine for ignition", and adds that backfire and afterfire through the carburetor "will not harm the engine at all!"

Champion's shutdown steps for the 201530 begin with every load turned off and unplugged. Then: "Let the generator run at no-load for several minutes to stabilize internal temperatures of the engine and generator."

Why is my generator knocking?

Knocking points to fuel, overload or engine wear. On the Predator 3500 the first fix is a tank of fresh, stabilized 87+ octane gasoline, the second is "Do not exceed equipment's load rating", and timing, deposits or a worn engine go to a qualified technician.

Briggs & Stratton adds a cause that the Predator table leaves out: "An improper spark plug gap could lead to engine knocking and poor performance." A knock that survives fresh fuel, a lighter load and a correctly gapped plug is a reason to stop running the machine. The Predator manual says "If abnormal noise, vibration, or excess smoking occurs, have the problem corrected before further use."

A hiss when you pull the starter

Hissing on the recoil pull points to a compression leak. Harbor Freight's Predator 3500 table notes "Hissing noise will occur when trying to start" under two compression faults: a loose or broken spark plug, and a loose cylinder head or damaged head gasket.

The plug comes first. "Tighten spark plug. If that does not work, replace spark plug." If the hiss persists, the head is next, with a new head gasket if tightening does not cure it.

Rattles, shaking and loose parts

Some shaking is part of normal running. "Generators vibrate and bounce during normal operation," reads the Westinghouse iGen1500c manual, and WEN's 56450iX manual also accepts vibration in normal use. Both want the generator and its cords checked afterward for vibration damage. Too much shaking is a reason to stop. Champion's manuals list "Equipment vibrates excessively" among the conditions under which the generator should not be used at all.

A rattle has no row in any troubleshooting table here, so the closest guidance is the inspection before each start. Westinghouse asks owners to "Inspect for loose bolts, fluid leaks, and other signs of wear." Firman's P03504 start-up steps check that the "spark plugs, muffler, fuel cap, and air cleaner are all in place", and its schedule covers exhaust leaks ("Retighten or replace gasket if necessary.") along with fittings and fasteners.

Harbor Freight counts heat shields among the guards to keep "in proper working order" on the Predator 3500, and asks you to turn it off, let the engine cool and disconnect the spark plug cap before any inspection. On Generac's iQ3500, the fittings and fasteners check is a job for an Independent Authorized Service Dealer.

Why does my standby generator run by itself?

A home standby generator that starts on its own, runs a few minutes and shuts off is exercising. On Generac's 10 to 26 kW air-cooled models the run lasts "approximately five minutes", weekly, biweekly or monthly, and household loads stay on utility power unless it fails.

The sound changes partway through. With Quiet-Test on, the unit "will run at operating speed for approximately five seconds, then drop speed", reaching the low Quiet-Test speed after about 40 seconds, according to the Generac air-cooled owner's manual. "If Quiet-Test is disabled, generator will exercise at the rated rpm." Both speeds are rated. For the 10 kW model 7257 the low-speed exercise figure is 49 dB(A), and a normal load brings 61 dB(A), each taken 7 meters from the front, on our Generac generator decibel chart.

A standby unit that runs rough gets a separate row, "Engine starts hard and runs rough". The causes are a plugged or damaged air cleaner, faulty spark plugs, fuel pressure outside 10 to 12 inches of water column on LP gas or 3.5 to 7.0 on natural gas, a fuel selector in the wrong position, valves out of adjustment, and an internal engine issue, which goes to the dealer.

When to stop and call for service

Stop running a generator that sparks, smokes, loses its output or shakes hard. Champion's manuals cover all four in three lines of their list of when not to use one: "Electrical output is lost", "Equipment sparks, smokes or emits flames" and "Equipment vibrates excessively".

Past that, each maker draws its line at the parts inside the engine. Honda sends rough idle, misfiring and backfiring to its dealers. Champion's help line takes a defective governor or a lean carburetor, and Firman's service facilities take a mixture that runs rich or lean. Westinghouse's customer service handles any fuel, ignition or stuck valve fault, the Predator manual sends timing, valve and wear problems to a qualified technician, and Generac routes internal standby engine issues to its dealers.

While you troubleshoot, the carbon monoxide rules in your manual still apply, including where the generator sits. Our page on generator noise and neighbors covers placement and distance.

How loud is a generator that is running properly?

That depends on its size and load. Honda's EU2200i is rated 48 dB(A) at a quarter load and 57 at rated load, 7 meters away, the lowest pair in its class in our quietest generators guide.

Across a whole brand the range is wide. Honda's 13 models run 42 to 73 dB(A) at 7 meters on our Honda generator decibel chart, and Champion's run 53 to 79 dBA from 23 feet on the Champion chart, with no load named. Those figures rate a whole machine, not a fault. None of the makers here gives a decibel level that marks a fault, so a generator that sounds wrong is judged by the symptoms above rather than by a number.

Quieter running, placement and buying

To lower the noise of a generator with nothing wrong, read how to make a generator quieter, which runs from eco mode by brand to load habits and the exhaust. Campground hours and local rules sit with placement on the neighbors page.

For a replacement, compare the quietest inverter generators under $1,000, the quietest dual fuel generators and the quietest home standby generators. A different small engine with many of the same faults is covered in lawn mower noises.

Harbor Freight's site turns away automated requests, so the Predator 3500 manual was read in an Internet Archive copy of Harbor Freight's own file. No generator was run or taken apart for this page.

What makers publish

The noise figures makers print for models in our buying guides, word for word, with any setting or distance they give. Figures taken under different conditions are not comparable, so this list does not rank them.

The quietest generators for camping and RVs

ModelNoise figure, as published
Honda EU2200i 2200 watt 120V inverter generator with CO-MINDER48 dB(A) at 1/4 load, 57 at rated load. Distance not stated
Honda EU1000i 1000 watt 120V inverter generator with CO-MINDER42 dB(A) at 1/4 load, 50 at rated load. Distance not stated
Champion 2500W Inverter53 dBA from 23 feet. Load not stated
WEN 56450iX Super Quiet 4500-Watt RV-Ready Portable Inverter Generator with Fuel Shut-Off and CO Watchdog58 dBA at quarter load, 22 feet
Honda EU3200i 3200 watt 120V inverter generator with CO-MINDER54 dB(A) at 1/4 load, 58 at rated load. Distance not stated

All 7 models in the guide

The quietest inverter generators under $1,000

ModelNoise figure, as published
WEN 56450iX Super Quiet 4500-Watt RV-Ready Portable Inverter Generator with Fuel Shut-Off and CO Watchdog58 dBA at quarter load, 22 ft
WEN 56235iX Super Quiet Ultra Lightweight 2350-Watt Portable Inverter Generator with Fuel Shut Off and CO Sensor51 decibels at quarter load. Distance not stated
Westinghouse iGen2800DFc Dual Fuel Inverter Generator with CO Sensor62 dBA at 25% load, 25 ft (table); 52 dBA in text
A-iPower SC2000i 2000 Watt Portable Inverter Generator with Yamaha Engine62 dBA at half load, 21 ft (7 m)
Pulsar PG2300iS 2,300 Watt Inverter Generator59 dB from 15 ft. Load not stated

All 6 models in the guide

The quietest dual fuel generators

ModelNoise figure, as published
Champion 2500W Dual Fuel Inverter with CO Shield (201530)53 dB(A) from 23 ft. Load not stated
WEN DF450i Super Quiet 4500-Watt Dual Fuel RV-Ready Portable Inverter Generator with Fuel Shut-Off58 dBA at 25% load, 22 ft
WEN DF525iX 5250-Watt Dual Fuel Electric Start Inverter Generator62.5 dBA at 25% load, 22 ft
Westinghouse iGen2800DFc Dual Fuel Inverter Generator with CO Sensor62 dBA at 25% load, 25 ft
Champion 4500W Electric Start Dual Fuel Inverter with CO Shield (201319)61 dB(A) from 23 ft. Load not stated

All 7 models in the guide

The quietest home standby generators, by exercise and running noise

ModelNoise figure, as published
Generac 10kW Home Standby Generator with Power Zone 200 controller (cellular)49 dB(A), Quiet-Test low speed, front of unit
Kohler 24RCLA 24kW liquid-cooled home standby generator52 dB(A), lowest of 8 points, no load
Generac 24kW Home Standby Generator with Power Zone 200 controller (cellular)55 dB(A), Quiet-Test low speed, front of unit
Generac 18kW Home Standby Generator with Power Zone 200 controller (cellular)55 dB(A), Quiet-Test low speed, front of unit
Kohler 26RCA 26kW air-cooled home standby generator56 dB(A), lowest of 8 points

All 6 models in the guide

Frequently asked questions

Why is my generator surging with no load?

Start with warm-up and the choke. DuroMax says to keep its idle control off until the engine is warm so the unit does not try to idle down early, and Generac and Champion both list the choke or start dial in the wrong position. If the surge stays once the engine is warm, the hunting rows in the Champion, WEN and Firman manuals point to the carburetor, the fuel valve or filter, and the air filter.

Why does my generator rev up and down?

Often because the load changes. Generac's iQ3500 manual says speed that "increases and decreases" is normal as loads vary, and an idle or eco switch drops the engine to a slow speed with nothing plugged in, then brings it back when a load arrives. Revving with a steady load and the switch off is the hunting that maker tables trace to fuel and air problems.

Can old gas make a generator surge?

Yes. Honda says fuel can deteriorate in as little as 30 days and leave gum that clogs the fuel system, and Briggs & Stratton calls stale fuel, dirt and debris the most common reason equipment runs poorly. The remedy the makers give is the same: drain the tank and carburetor and refill with fresh gasoline, adding a stabilizer if the fuel will sit.

Why does my generator pop when I turn it off?

A bang after shutdown is what Briggs & Stratton calls afterfire, and it puts the cause on shutting the engine off at high RPM. Champion's 201530 manual has owners unplug every load and let the generator run with no load for several minutes before stopping it. Briggs says backfire and afterfire through the carburetor do not harm the engine.

Is it normal for a generator to vibrate?

Some vibration, yes. Westinghouse and WEN both say generators vibrate in normal use and ask owners to check the machine and its cords for vibration damage. Champion draws the line at excessive vibration and says not to use the generator at all when it happens. Loose bolts are part of the pre-start checks in the Westinghouse, Firman and Predator manuals.

How we reviewed this article

Every statement here comes from the 13 maker documents, standards and agency pages listed under Sources, quoted where the wording matters. We did not measure, inspect or repair anything ourselves. Each substantive revision is dated below. How we work

  1. Current version

    Generator noise page goes live, quoting troubleshooting tables and support pages by Honda, Champion, Generac, Harbor Freight (Predator), WEN, Westinghouse, Firman, DuroMax and Briggs & Stratton.

  2. First published, written by Stanley Alu.

Sources

All 13 sources

Written by

Stanley Alu

Founder and editor

I founded QuietSpecs after running a product review blog, and I built it around the spec that is hardest to pin down. With noise, makers tend to quote the quietest setting they can find, or nothing at all. So I read the spec sheets, manuals and certification directories, quote each figure with the setting it describes, and say so plainly when a maker publishes none. I do not test products or measure decibels, and no brand pays for a place in a guide.

How we compare products

Related buying guides

More in Why Is It Noisy