A hot tub that starts to growl, squeal or gurgle is most often telling you about its pump. The spa makers who publish troubleshooting pages trace the common sounds to a short list of causes: too little water, clogged flow, trapped air after a refill and, for a squeal, worn pump bearings. A few searches fall outside their pages entirely. Nothing they publish covers a tub that hums but will not work, clicks at night or gets loud only while heating, and not one of them publishes a spa's sound level in decibels.
Everything below is quoted from troubleshooting pages published by AstralPool (the Fluidra brand, on its Australian site), Caldera Spas and MSpa, with an airlock how-to from Arctic Spas. We did not run, measure or take apart any hot tub for this page.
Why is my hot tub making noise?
A hot tub making noise usually has a pump short of water, a clog, an airlock after refilling or, if it squeals, failing bearings, by the makers' accounts. Match the sound first:
| Sound | Cause the maker gives | Maker |
|---|---|---|
| Growl or grumble from the pump | Not enough water flowing through the pump, usually clogs | AstralPool |
| High-pitched squeal | Bad pump bearings | AstralPool |
| Pumps running, no water from the jets | Most likely an airlock, often after a refill | Caldera Spas |
| Inflatable spa pump loud in general | What the pump sits on | MSpa |
| Inflatable spa loud with BUBBLE on | A clogged one-way valve in the pump | MSpa |
| Humming but not working | Not explained in any spa maker page we found | None |
Before anything else, Caldera starts its own pump troubleshooting at the ground fault circuit interrupter (GFCI). When it trips, "it cuts off all electricity to your spa", and pressing its reset button restores power.
Why is my hot tub pump growling or grumbling?
A growling hot tub pump is short of water, according to AstralPool, which says the sound "is often related to a lack of water flowing through your pump." It names clogs in the circulation system as the usual cause.
The quick fix on AstralPool's spa troubleshooting page is to open every valve near the pump and top off the spa water so enough can flow.
Caldera Spas explains why the level matters. Its pump troubleshooting article says water is lost over time to evaporation and spillage, and "A low water level will cause the hot tub's pump to struggle" to build the pressure the jets need. The ideal level, by Caldera's measure, is "about an inch above the highest jet." Check it whenever you do routine maintenance.
Dirty filters come next on Caldera's list, since they "can block water flow and cause a similar issue." Low water and dirty filters can both trip the heater high-limit, which leaves the spa unresponsive until it cools down or the fault is fixed. Clean the filters as your owner's manual sets out.
Why is my hot tub pump squealing?
A squealing spa pump typically has bad bearings, says AstralPool. It warns that the squeal is generally more off-putting than a growl and that "the noise will only worsen over time."
AstralPool's page goes on: "The first thing to do is lubricate the bearings, this will alleviate the sound for the time being, but you'll likely need to replace the circulation pump down the track." We quote that advice and do not endorse it. Caldera, MSpa and Arctic Spas say nothing about lubricating bearings.
On replacing a worn pump, Caldera says a trained technician can do it.
Airlocks after draining and refilling
An airlock is air trapped in the spa's plumbing after a water change, and Caldera calls it the most likely culprit when "you turn on your spa, hear the pumps running, but see no water flowing from the jets."
Here is how Caldera describes it. When a spa is drained, air takes the water's place, and some of it can stay behind on a refill and act as a plug in the piping. The first instruction is to "Turn the spa off immediately to prevent damage to the heater and the pumps."
The steps then set the heater below the air temperature, open adjustable jets and diverter valves fully, and run the jets on high for 10 to 15 seconds to push the air out. If no air bubbles show by the third or fourth attempt, Caldera wants you to stop and call the dealer while the spa is still under warranty.
Bleeding air at the pump
With the power disconnected and the access panel off, Caldera has owners loosen the union above the pump, without removing it, until water flows. Then they tighten it, run the jets and check the union for leaks. If all is well, the panel goes back on.
AstralPool's version is shorter: "loosen the top fitting on your pump until you hear air or see water escape", then tighten it again. Some systems, it adds, have small bleed screws at the end of the pump.
Arctic Spas, in its air lock video guide, says airlocks happen when the water level drops too low or after a water change, and that flow sensors often show an error such as "FLO" on the topside display. Do not disable that feature, Arctic says. Its page describes no sound at all.
Why is my hot tub gurgling?
None of the spa makers we found ties gurgling to a cause or calls it normal. The closest maker material is the airlock guidance above.
That link goes only as far as the makers do. Caldera and Arctic Spas both place airlocks after a drain and refill, and Arctic adds a low water level as a trigger. If the gurgle comes with weak or missing jet flow, the airlock steps apply; a gurgle with normal flow is not covered by any document here.
For pool equipment, our page on pool heater noises covers air sounds after a heater starts.
Loud inflatable hot tub pumps
An inflatable spa pump that seems too loud may simply be badly placed. MSpa's Noisy Pump page opens with "The issue may be caused by what the spa pump is sat upon."
MSpa's setup checks are three: the spa on "a flat, hard surface", the pump located away from any walls, and no pump or spa on "any gravel or sharp surfaces."
If those are right and the noise stays, MSpa turns to the functions. A spa that gets loud "when BUBBLE in ON" (MSpa's wording) can have a clogged one-way valve in the pump. MSpa also says to check the filter pump if the spa gets loud once Filter, Heater, UVC or Ozone is switched on. The page lists those functions and stops, so there are no further steps to pass on.
We also looked for an Intex document on pumps grinding or a spa too noisy in filtration mode. The Intex pages that turned up do not mention noise.
Humming but not working, or humming then stopping
Nothing we found from a spa maker explains a hot tub that hums but does not work, or one that hums and then stops. Claims about failed capacitors and breakers come from retailer blogs, which we do not use as sources.
What Caldera does say is that the pump may be fine while something else stops the spa. Its spas shut down "to avoid damage" when they sense a power supply or electronic fault, and an airlock or sensor issue can keep a spa from running. The order of checks Caldera gives is the GFCI, then a thirty-second power reset at the breaker, then the water level, the filters and airlocks. Past that, it sends owners to the dealer.
The makers are silent on a few more searches too: a hot tub that is noisy at night, noisy only while heating, clicking or rattling. No maker document we read explains a hissing auto shut-off valve either.
When to call a technician
Call a spa dealer or technician when the pump squeals from worn bearings, when the airlock steps fail, or when the spa leaks. AstralPool expects a squealing circulation pump to need replacing.
Caldera's article says "if the spa is leaking water, call your local dealer immediately", and warns that a do-it-yourself repair may void the warranty. A pump that has worn out or been damaged can be replaced by a trained technician.
Electrical faults get the firmest line. AstralPool puts it this way: "Water and electricity are deadly when mixed, so we always recommend contacting experts if working with electricity." A pump that is not running at all, by AstralPool's account, "likely needs replacing or repairing by a professional."
How loud is a hot tub?
The hot tub makers whose pages we opened publish no decibel figure for a spa or its pump, and QuietSpecs has no hot tub buying guide.
Without a published figure there is no normal level to compare against. For how sound levels and distance work in general, see our decibel chart and noise distance calculator.
Related guides and explainers
Pool equipment shares a lot with spa pumps. Our page on how to make a pool pump quieter covers squealing bearings from the pool makers' side, and pool heater noises explains what heaters and heat pumps do at start-up. For replacements with published figures, compare the quietest pool pumps and the quietest pool heat pumps.